6-3
Alarm Display
Digital
RUN (Green)
Drive
Explanation
Causes and
Operator
ALARM (Red)
Status
Corrective Actions
BB (External baseblock)
Check the external circuit
Baseblock command at
(sequence).
multi-function terminal is
active, the drive output
Blinking
is shut OFF (motor coasting).
Temporary condition is
cleared when input command
is removed.
EF (Simultaneous FWD/
Check the external circuit
REV run commands)
(sequence).
When FWD and REV
run commands are
Blinking
simultaneously input
for over 500ms, the
drive stops according
Warning
to parameter n005.
only.
STP (Operator function
Open FWD/REV
Fault
stop)
command of control
contacts
circuit terminals.
do not
is pressed
change
during running by the
state.
control circuit terminals
FWD / REV command.
The drive stops according
Blinking
to parameter n005.
STP (Emergency stop)
Check the external circuit
Drive receives emergency
(sequence).
stop alarm signal.
Drive stops according
to parameter n005.
FAN (Cooling fan fault)
Check the following:
Cooling fan is locked.
• Cooling fan
• Cooling fan wiring is not
Blinking
connected.
Table 6-1. Alarm Displays and Corrective Actions - Continued
or
Содержание GPD 315
Страница 1: ...GPD 315 Technical Manual Magne Tek ...
Страница 20: ...1 14 ...
Страница 32: ...3 2 ...
Страница 76: ...5 40 PID Block Diagram ...
Страница 80: ...5 44 ...
Страница 96: ...A1 8 ...
Страница 100: ...A3 2 ...
Страница 102: ...A4 2 ...
Страница 110: ...A6 6 ...
Страница 114: ......
Страница 116: ......