Enrange Flex M Pre-Engineered Modular Receiver Manual
October 2014
Page 8 of 31
Figure 2: Example of Flex M Mounted in an Enclosure
2.3 INSTALLATION
1.
Be sure to mount the receiver antenna in direct line-of-sight of the operator and free from
all obstructions.
2. Do not mount the receiver near high levels of electric noise, such as an unshielded variable
frequency drive, as it may cause minor interference. When mounting the Flex M near
unshielded variable frequency drive,
Magnetek typically recommends that the Flex M and
all antenna cable routing be mounted a minimum of 24 inches from all unshielded
variable frequency drives and cables
.
3. Allow adequate room for mounting the receiver. Make sure to allow a minimum of 5” between
connector and nearest surface to allow for cable harness connections.
4. For best reception and to help protect connectors from moisture and water damage, mount the
receiver in an upright position. Mount with back flush against a flat surface to protect vents from
spray.
5. If obstructions cannot be cleared, or the unit must be mounted inside a metal enclosure, the
remote antenna should be used (see Figure 2).
6. Do not enclose the antenna in steel. For best reception, keep all metal objects away from the
antenna.
Consult the factory for more information regarding your application.
7. The supply power to the Flex M system must have a master disconnect and should be fused.
8. The Flex M modules are installed on a 35mm Din rail. To install the individual modules on the
Din rail, hook the bottom of the module on the Din rail and swing the top of the module to the rail
until a click is heard or felt.
9. After the modules are placed on the rail, they are slid together so they nest together. Rail clamps
are suggested to prevent the module bundle from sliding freely on the rail.
10.
Modules MUST be installed so that the RF/CPU module is on the left end of the rail and the
power supply module is on the right end of the rail.
NOTE: Magnetek strongly recommends the use of external fuses and circuit disconnects for all Flex
Modules. Consult factory for more information.
Flex Flex Flex Flex
Содержание FLEX M Series
Страница 21: ...Enrange Flex M Pre Engineered Modular Receiver Manual October 2014 Page 18 of 31...
Страница 22: ...Enrange Flex M Pre Engineered Modular Receiver Manual October 2014 Page 19 of 31...
Страница 23: ...Enrange Flex M Pre Engineered Modular Receiver Manual October 2014 Page 20 of 31...
Страница 28: ...Enrange Flex M Pre Engineered Modular Receiver Manual October 2014 Page 25 of 31...
Страница 29: ...Enrange Flex M Pre Engineered Modular Receiver Manual October 2014 Page 26 of 31...