Electrification FS Conductor Bar System Instruction Manual
October 2019
Page
29
of
34
Chapter 9.0: Transfer Cap
9.1: FS-TCAP
9.1.(a):
Be sure set screws provided are backed out and will not interfere with installation.
9.1.(b):
Slide transfer cap over end of conductor bar. The transfer cap should slide 1-7/16” over
the end of the bar (3/4” over the bar cover) until the bar stops against the inside of the cap.
9.1.(c):
Tighten each set screw equally against the conductor bar; be sure the set screw is
tightened a minimum 1/16” below the outer surface of the transfer cap.
9.1.(d):
For best performance be sure the transfer caps are aligned as shown below.
NOTE: Tools Required: 3/32” Allen Wrench
Transfer Cap Alignment Specifications
.250” max.
Max. Vertical
Misalignment .125”
Max. Lateral
Misalignment .125”