REPLACING BATTERY METER
Note: It is important to keep the CooLift upright at all times.
1. Place the CooLift on a level flooring surface.
2. Engage the holding brake.
3. Turn off the main power switch.
4. Remove the battery box (see Replacing Battery Box in the CooLift Service Manual) through and
including step 7, unplugging the battery box from the CooLift.
5. To release the battery meter from the CooLift enclosure, reach underneath the enclosure and
find the tabs located on both sides of the meter (see Figure 1). Squeeze the tabs inward and
ease the battery meter upward and out of the enclosure.
6. Disconnect the red wire (+) from the BATTERY (+) terminal of the battery meter and ensure the
wire end does not fall back through the hole of the enclosure.
7. Disconnect the black wire (-) from the BATTERY (-) terminal of the battery meter and ensure the
wire end does not fall back through the hole of the enclosure.
8. Disconnect the white wire from the KEYSWITCH terminal of the battery meter and ensure the
wire end does not fall back through the hole of the enclosure.
9. Check to be sure that the rubber gasket is in place on the new battery meter - install the rubber
gasket to the battery meter if necessary.
10. Connect the black wire (-) to the BATTERY (-) terminal of the battery meter (see Figure 2).
11. Connect the white wire to the KEYSWITCH terminal of the battery meter (see Figure 2).
12. Connect the red wire (+) to the BATTERY (+) terminal of the battery meter (see Figure 2).
13. Snap the meter back into place in the enclosure shelf, making sure that the battery indicator
label is at the top of the meter (see Figure 3).
14. Recheck all connections for correct wiring placement and tightness.
15. Reinstall the battery box (see Replacing Battery Box in the CooLift Service Manual).
Figure 1
Figure 2
Figure 3
Press tabs inward
Description
Qty.
Part Number
Battery charge meter
1
62033