9
3
8
4
2
1
5
8. SETTING UP
CONTROLS (pag. 4)
1
POWER ON-OFF SWITCH AND LAMP. Two-position switch with led turn on the switch, led on, the
machine is turned on and the pump is activated, filling the boiler with water.
2
RESISTOR ACTIVATED PILOT LIGHT. Turns on the electric power supply to the boiler heating
elements.
3
HOT WATER SUPPLY SWITCH (MS MODELS). Two-position switch with led: turn on the switch, led
on, hot water is dispensed; turn off the switch, led off, dispensing of hot water is interrupted. Dose of hot
water supply switch (ES Models). Press for a second the led light up and a dose of hot water is obtained.
4 CUPS
WARMER
CONTROL. Turns on the electric power supply to the cups warmer heating elements.
5 COFFEE DISPENSING SWITCH. (MS MODELS). Two-position switch with led: turn on the switch, led
on, coffe is dispensed; turn off the switch, led off, dispensing of coffee is interrupted. Electronic coffee
delivery button panel. Five buttons with relative led. Buttons A-B-C-D: Press the button for a second, led
on, release button; coffee is dispensed. The led turns of and dispensing ceases.
Button E: Press the button for a second, led on, release the button; coffee is continuously dispennsed. Press
the button for a second, led off, release button; continuous dispensing of coffee ceases.
6
WATER LEVEL LAMP. Green lamp. Lamp on indicates that the water level is above minimum.
7
ORANGE WATER SUPPLY LAMP. Orange lamp. Lamp on indicates that the water level is below
minimum and that the autolevel has been activated.
If the lamp stays on, this means that the autolevel has not been activated. Ensure that the water supply
tap is open, otherwise the machine must be switched of and authorized personnel must be consulted.
8
STEAM TAP. Tap: turn in an anticlockwise direction to open and clockwise to close.
10
LEVEL INDICATOR. Minimum and maximum water level indicator. Visual control of water level in
boiler.
11
GAUGE WITH MOBILE NEEDLE ON A FIXED DIAL WITH A DOUBLE SCALE AND COLOUR
INDICATOR AREAS. Visual control of the pump and of the boiler pressure.
12
COFFEE DISPENSING UNIT.
13
VALVED GAS TAP (ON SPECIFIC MODELS). Valved gas power tap (models with gas heating). Open:
vertical position; Closed: turn 90° in clockwise direction.
14 Gas lighter (on specific models). Piezoelectric button (models with gas heating). Firing button: press down
firmly to give off the spark to light the gas for the burner.
15
Manual water supply button. Manual filling button. Press down to fill the boiler.
16 Flame control. Control window (models with gas heating). Visual control of lighting and functioning of the
flame of the gas burner.
E
A
B
D
C