Page 26
6. The flue must serve only one appliance.
7. If any terminals, cowls or chimney pots are fitted on the flue, ensure that they are suitable
use with a decorative gas fire and do not restrict the cross sectional area of the flue.
Please consult the manufacturer of the terminal/cowl/chimney pot for guidance.
3.3. Technical Data
Natural Gas
LPG
Nominal maximum heat input
9.0 kW (gross)
8.5 kW (gross)
Setting pressure (Cold)
14.0 mbar ±1.0mbar
34.0 mbar ±1.0mbar
Minimum heat Input
4.0 kW (gross)
4.0 kW (gross)
Minimum setting pressure
3.0 mbar ±0.2 mbar
8.0mbar ±0.5 mbar
Gas
G20 (Natural Gas)
G31 (Propane)
Injector Size
95
55
Gas inlet connection
8mm
8mm
Control valve
BM/Mertik GV34/
GV60
BM/Mertik GV34/
GV60
Pilot
SIT OxyPilot 9039
SIT OxyPilot 9223
Weight Inset Model
Thermobox Model
4.0kg
4.0kg
3.4. General Dimensions
E
B
D
A
Figure 43 - Thermobox Dimensions
Standard
Dimensions
Trim
Switch
A
580mm
580mm
B
555mm
555mm
C
450mm
450mm
D 253mm 228mm
E
535mm
535mm
Table 1