10 MAGICFX
®
PSYCO2JET
—
User and Installation Manual
Operating of the addresses in RAW mode results in the following:
DMX Address
DMX Value (decimal)
Result
Safety address
0
99
Device disabled
100
155
Device enabled
156
255
Device test mode (CO
2
output is disabled)
Start address (Angle)
0
126
-90° to -0.7°
127
128
Center position
129
255
+0.7° to +90°
Start a 1 (Speed)
0
255
Minimal speed -> Full
speed
Start a 2 (Output)
0
199
Valve off
200
255
Valve on
Operation of the DMX addresses in RAW mode
When you link multiple machines with DMX, we advise you to use the same Safety
address for all machines.
CAUTION
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal reliability.
1.7
PRESET MODE
In PRESET mode, the operator controls the output of the MAGICFX
®
PSYCO2JET with the
help of one of the preprogrammed presets. With DMX the operator controls the
following variables:
• The selected preset
• The speed of rotation of the output pipe
• The directions of the output pipe
• The ´Go´ mode:
• OFF
(No movement)
• Continuous
(The preset is repeated continuously)
• Step in preset (Step by step)
PRESET mode is selected from the operator menu. Check Section 1.5 for the menu
structure.
The MAGICFX
®
PSYCO2JET is programmed with 10 presets. Each preset is a unique
sequence of pulses and/or sweeps of CO
2
, see figures.
Содержание PSYCO2JET
Страница 1: ...PSYCO2JET CO2 FX PART01127 rev 01 01 USER AND INSTALLATION MANUAL ENGLISH...
Страница 38: ...38 MAGICFX PSYCO2JET User and Installation Manual...
Страница 39: ......
Страница 40: ...WWW MAGICFX EU...