MAGICFX
®
PSYCO2JET
—
User and Installation Manual
17
WARNING
Inadequate installation and/or operation of a CO
2
powered
machine and CO
2
cylinders can lead to death or serious injury.
Always follow the instructions from this manual, from your CO
2
supplier and from local authorities.
2.3
INDOOR USE
The MAGICFX
®
PSYCO2JET is designed for outdoor use and use in well-ventilated
indoor spaces. When used indoors, make sure you take the necessary preparations.
These preparations could include, but are not limited to:
• Consulting your CO
2
supplier.
• Calculating the reduction of oxygen for the indoor space.
• Checking the location for spots where CO
2
could accumulate and taking
preventive actions.
• Installing CO
2
monitoring devices that will warn for hazardous CO
2
levels.
DANGER
Do not use the MAGICFX
®
PSYCO2JET in poorly ventilated
confined spaces. Exposure to high levels of CO
2
gas can cause
symptoms like headache, nausea, loss of consciousness or even
death.
2.4
RIGGING
Please follow the European and national guidelines for safe rigging and trussing.
2.5
NOISE LEVEL
The environmental noise level as measured at the ear is 118 dB(A). This level of noise
is only reached during the short instances that the CO
2
output is active. Therefore
hearing protection is not necessary.
WARNING
Do not operate the MAGICFX
®
PSYCO2JET close to yourself or to
others for a long period of time. If you experience any hearing
loss or ringing in the ears, you should immediately stop using the
unit.