MAGIC FX PSYCO2JET Скачать руководство пользователя страница 37

MAGICFX

®

 PSYCO2JET 

 

User and Installation Manual

  37

EC DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY

According to Annex III A Low Voltage Directive 2014/35/EU + Machinery Directive 

2006/42/EC

MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the 
product with the following specifications:

Name machine

PSYCO₂JET

Type

: MFX1117

Voltage

: 100-250Vac 50-60Hz

Serial number

: on product

Year of construction

: on product

Is in conformity with the minimal safety regulations as stated in the following directive(s):

EMC (2014/30/EC) ElectroMagnetic Compatibility

RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances

WEEE (2012/19/EU) Waste Electrical & Electronic Equipment

The following harmonized standards were applied:

NEN-EN-ISO 12100:2010 Safety of machinery - General principles for design - Risk 
assessment and risk reduction.

NEN-EN-IEC 60204-1:2006, Safety of machinery - Electrical equipment of machines - Part 1: 
General requirements.

NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3: 
Generic standards - Emission standard for residential, commercial and light-industrial 
environments.

Original declaration of conformity

Translation of the original declaration of conformity

Name manufacturer

: MAGIC FX BV

Address

: Schouwrooij 27, 5281 RE BOXTEL

Country

: The Netherlands

CEO

: B. Veroude

Date

: 17-01-2017

Signature

:

Содержание PSYCO2JET

Страница 1: ...PSYCO2JET CO2 FX PART01127 rev 01 01 USER AND INSTALLATION MANUAL ENGLISH...

Страница 2: ...Any brand names mentioned in this manual are registered trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use use ot...

Страница 3: ...10 1 8 RDM capability 14 2 Blast safely 16 2 1 General safety rules 16 2 2 CO2 16 2 3 Indoor use 17 2 4 Rigging 17 2 5 Noise level 17 2 6 Safety symbols 18 2 7 Precautions for operation 18 3 Let s bla...

Страница 4: ...avoided will result in death or serious injury This signal word is to be limited to the most extreme situations WARNING Indicates a hazardous situation that if not avoided could result in death or se...

Страница 5: ...s mounted on a 180 rotatable pipe driven by an electric motor By blasting and varying the output direction the MAGICFX PSYCO2JET delivers spectacular effects The MAGICFX PSYCO2JET is outfitted for ope...

Страница 6: ...ature 10 C 14 F Maximum Temperature 50 C 122 F Humidity Relative 20 to 90 non condensing IEC 60529 IP Rating IP23 Electrical Voltage Input 100 250 Vac Voltage Frequency 50 60 Hz Power Consumption 35 W...

Страница 7: ...MFX1103 CO Bottle to Hose Connector MFX1115 CO Bottle to Hose Connector 90 Degrees MFX0313 Schuko to Neutrik powerCON TRUE1 cable 1 5 m X Accessories Please contact MAGIC FX for additional possibiliti...

Страница 8: ...hold for 5 seconds Reset Errors DMX RDM Settings Error History Con guration Information RDM ON OFF Nozzle Mirror Function ON OFF Nozzle Block Left 140 255 Nozzle Calibration 5 5 Nozzle Block Right 0...

Страница 9: ...closed RAW mode is selected from the operator menu Check Section 1 5 for the menu structure 0 90 90 OUTPUT PIPE ROTATING NOZZLE Output angle when facing the front side of the unit In RAW mode the MAGI...

Страница 10: ...r all machines CAUTION Always plug in a DMX Terminator into the DMX output of the final unit in the control sequence Using a DMX Terminator improves signal reliability 1 7 PRESET MODE In PRESET mode t...

Страница 11: ...ET NUMBER SWEEP PULSE LONG PULSE 0 90 90 45 45 2 1 2 0 90 90 45 45 5 1 2 3 4 5 0 90 90 45 45 1 1 0 90 90 45 45 3 1 2 3 0 90 90 45 45 4 1 2 3 4 SEQUENCE NUMBER LEFT DIRECTION 3 MOVEMENT OF NOZZLE Prese...

Страница 12: ...5 45 10 8 PRESET NUMBER SWEEP PULSE LONG PULSE 0 90 90 45 45 RANDOM 6 0 90 90 45 45 8 1 2 3 SEQUENCE NUMBER LEFT DIRECTION 3 0 90 90 45 45 9 5 6 7 1 3 4 2 MOVEMENT OF NOZZLE 0 90 90 45 45 7 4 1 2 3 Pr...

Страница 13: ...l Result Safety address 0 99 Device disabled 100 155 Device enabled 156 255 Device test mode CO2 output is disabled Start address Preset 0 24 1 Single pulse straight up 0 25 49 2 2 pulses distributed...

Страница 14: ...MX we advise you to use the same Safety address for all machines CAUTION Always plug in a DMX Terminator into the DMX output of the final unit in the control sequence Using a DMX Terminator improves s...

Страница 15: ..._DESCRIPTION X DMX_START_ADDRESS X X IDENTIFY_DEVICE X X DEVICE_LABEL X X FACTORY_DEFAULTS X X DMX_PERSONALITY X X DISPLAY_INVERT X X PAN_INVERT X X RESET_DEVICE X RDM parameters RDM parameters are su...

Страница 16: ...thorised people and animals do not obtain access to the MAGICFX PSYCO2JET Make sure there are no freestanding objects or objects that can be damaged by the MAGICFX PSYCO2JET within the output distance...

Страница 17: ...O2 could accumulate and taking preventive actions Installing CO2 monitoring devices that will warn for hazardous CO2 levels DANGER Do not use the MAGICFX PSYCO2JET in poorly ventilated confined spaces...

Страница 18: ...sts CO2 This can lead to death serious injury and or property damage Always inspect if the machine is mounted firmly and correctly as according to the instructions in this manual WARNING Missing or ob...

Страница 19: ...MAGICFX PSYCO2JET User and Installation Manual 19 4 m 15 4 m 4 m 15 Safety zone for stage mounted units 4 m 15 4 m 4 m 15 Safety zone for truss mounted units...

Страница 20: ...20 MAGICFX PSYCO2JET User and Installation Manual 3 LET S BLAST 3 1 INSTALL THE MACHINE 1 Flip the MAGICFX PSYCO2JET upside down 2 Loosen the rubber foots and rotate each stage bracket outwards 1 2...

Страница 21: ...MAGICFX PSYCO2JET User and Installation Manual 21 3 Firmly fasten the rubber foots 4 Flip the MAGICFX PSYCO2JET back...

Страница 22: ...MAGICFX PSYCO2JET User and Installation Manual 5 Mount the MAGICFX PSYCO2JET firmly on a stage 6 Inspect if the MAGICFX PSYCO2JET is mounted firmly 7 Take the necessary safety precautions see Section...

Страница 23: ...MAGICFX PSYCO2JET User and Installation Manual 23 3 2 MOUNT ON A TRUSS 1 Flip the MAGICFX PSYCO2JET upside down 2 Optionally you can remove the rubber foots and stage brackets...

Страница 24: ...SYCO2JET User and Installation Manual 3 Screw clamps into a pair of holes in x or in y direction Use two M10 twenty clamps for truss mounting product code MFX3103 Y Z X Y Z X 4 Mount the clamps firmly...

Страница 25: ...Installation Manual 25 5 Secure the MAGICFX PSYCO2JET onto the truss with use of the safety eye 6 Inspect if the MAGICFX PSYCO2JET is mounted firmly and secured correctly 7 Take the necessary safety p...

Страница 26: ...a 100 250 Vac 50 60 Hz power source 3 Connect the female connector of a 5 pole DMX cable in the DMX input DMX IN DMX OUT 5 pole female DMX 4 Connect the other end of the DMX cable to your DMX control...

Страница 27: ...onnect a DMX cable to the DMX output 4 Connect the other end to the DMX input of the next machine 5 pole female DMX IN DMX OUT DMX IN DMX OUT 5 pole male DMX 5 Use the display and buttons or a RDM con...

Страница 28: ...allation Manual 3 6 CONNECT CO2 1 Make sure that the safety channel is deactivated FX LED indicator on each machine is dimmed 2 Connect the CO2 hose to the CO2 quick connector 3 Connect a CO Bottle to...

Страница 29: ...PSYCO2JET User and Installation Manual 29 4 Connect the CO2 hose to the CO Bottle to Hose Connector on the CO2 cylinder 5 Open the CO2 cylinder 6 In case of multiple machines Repeat steps 1 5 for each...

Страница 30: ...m persons and hazardous objects 2 Activate the Safety address The FX LED indicator on each machine lights up 3 When it s time to blast activate the necessary operational addresses see Chapter 1 4 Enjo...

Страница 31: ...is dimmed 2 Close the CO2 cylinder In case of multiple machines connected in series Close all CO2 cylinders 3 Activate the Safety address again The FX LED indicator on each connected machine lights u...

Страница 32: ...d Installation Manual 7 Disconnect the CO2 hose from the CO2 Bottle to Hose Connector on the CO2 cylinder 8 Remove the CO2 Bottle to Hose Connector from the cylinder 9 Connect a CO2 Bottle to Hose Con...

Страница 33: ...2JET User and Installation Manual 33 10 Connect the CO2 hose to the CO2 Bottle to Hose Connector on the new CO2 cylinder 11 Open the CO2 cylinder 12 In case of multiple machines Repeat steps 7 11 for...

Страница 34: ...e of multiple machines connected in series Close all CO2 cylinders 3 Activate the Safety address again The FX LED indicator on each connected machine lights up 4 Activate the Start address for CO2 out...

Страница 35: ...tallation Manual 35 8 Disconnect the CO2 hose from the CO Bottle to Hose Connector on the CO2 cylinder 9 Remove the CO Bottle to Hose Connector from the cylinder 10 Disconnect DMX cable s and power ca...

Страница 36: ...electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take this product to designated collection points where it will...

Страница 37: ...lity RoHS 2011 65 EU Restriction of the use of certain Hazardous Substances WEEE 2012 19 EU Waste Electrical Electronic Equipment The following harmonized standards were applied NEN EN ISO 12100 2010...

Страница 38: ...38 MAGICFX PSYCO2JET User and Installation Manual...

Страница 39: ......

Страница 40: ...WWW MAGICFX EU...

Отзывы: