4 OPERATION, REGULATION AND SAFETY ELEMENTS
The combined boiler DP25 is equipped with a pellet burner control unit in a pellet
burner to ensure smooth operation of the system.
When switching to pellet mode (pellet indicator light is on), the pellet burner is
automatically put into operation after burning wood in the combustion chamber. After
switching back to the combustion mode, it is necessary to:
1.
Turn OFF the pellet burner.
2.
Switch ON wood button (LED diode - wood)
4.1 REGULATION ELEMENTS
Boiler regulator setting ecoTouch 850 enables setting of:
• boiler water outlet temperature
• Auto mode Fuel feeder and ventilator
• parameters for the setback mode
• Operation of feeder and fan hand
• The flow temperature of the circulating pump (Central heating)
• The storage tank
• Control pumps for hot
The controller is equipped with an input for room thermostat.
The external regulator - for boiler controller can be connected (potential- free) normal
room thermostat. The thermostat is connected by opening the controller box located at
the bottom part behind the of a burner screw. There are also slots for connection of the
pump.
4.2 SAFETY FEATURES
STB emergency thermostat
The STB safety thermostat represents the protection of the boiler against
overheating. After heating the boiler to a temperature above 95 ° C, the thermostat
switches off, thereby interrupting the power supply to the fuel substation. The boiler
output instantly decreases. To re-start the boiler it is necessary to unscrew the cover and
mechanically push the pin.