The boiler is placed:
• Basic environment AA5 / AB5 according to STN 33 2000-3
• Before the boiler, the min. 1000 mm
• The minimum distance between the back of the boiler and the wall is 400 mm
• at the fuel tank side a gap of min. 500 mm in case of removal of the feeding screw
• Minimum distance from the left sidewall 100 mm
• above the boiler at least 450 mm for the possibility of cleaning the exchanger and
filling the fuel
Location of the boiler to the electricity grid
The boiler must be positioned so that the plug in the socket (230V/50Hz) is always
accessible. The boiler connects to the el. network with a rigidly connected movable
supply terminated by a standardized fork
Protection against electric shock has to be ensured according to current STN EN (see
chapter 4.1).
Fuel location
For proper combustion in the boiler it is necessary to use dry fuel. Pellets are
recommended to be stored in their original packaging by the manufacturer (PET bags)
in a dry place. Fuel is forbidden to stow the boiler, store it next to the boiler at a
distance of less than 400 mm. The manufacturer recommends that the distance between
the boiler and the fuel min. 1 000 mm or place the fuel in a different room than the
boiler installed
The room where the boiler is installed must have a permanent supply and exhaust for
combustion and ventilation. The connection of the heating system pipe or DHW heater
piping must be carried out by an authorized person.
When connecting the boiler to the heating system, the drain valve must be
located in the lowest position and as closest to the boiler as possible.