background image

2. 

Installation & Configuration

 

This section provides complete instructions for mounting the M3 High Fidelity Multi-Channel Digital Audio 
Player on a Wall or Table.  It also illustrates all interface requirements to auxiliary equipment, including 
inputs and outputs. Configuration switch settings are provided. 

2.1. Installation 

Steps 

 
These are the general steps for installation.  
 
1.  Find a space on the wall or table. For table top applications, install included rubber feet.  Allow 

approximately 6 inches in front of, and 6 inches in back of the unit for user access to memory and 
wiring.  

2.  Mount the unit to the selected place with its wiring at least 18” away from power supply or other 

equipment that generates electrical noise.   

3.  If you are using the optional power supply, make sure there is a standard electrical outlet available. 
4.  Connect audio outputs. 
5.  Connect control inputs and outputs.  
6.  Set DIP switches to the desired operation. 
7.  Verify memory is installed. If the unit was programmed in the factory, the memory will already be 

installed in the unit. If you plan to create your own messages, the memory will be shipped 
separately. Refer to Section 5 for additional information on checking memory. 

8.  Connect and apply power.  
9.  Test unit operation. 

 

2.2. 

Configuration and Features (M3.1, M3.1+1, M3.2) 

 
This section documents the features and functions common to all versions of the M3. 
 

2.2.1. Power 

 
2 terminal pluggable connector.  
 

12 VDC at 1 amp 

- Ground 

 
The plug is a rising clamp style termination that accepts up to 16 gauge wire.  To insert wire loosen 
the screw on the top of the plug, insert the wire into the side of the plug, then tighten the screw.  
 

2.2.2. Audio Out 

 
Two, 3 terminal pluggable connectors. 
 

L - 

Left audio output, inverting 

 

Left audio output ground 

L + 

Left audio output, non-inverting 

 

R - 

Right audio output, inverting 

 

Right audio output ground 

R + 

Right audio output, non-inverting 

 
M3 supports balanced audio output. If unbalanced (single ended) is desired, use audio output non-
inverting and audio output ground. 
 
The plug is a spring clamp style termination that accepts up to 16 gauge wire.  To insert wire, insert 
a jewelers screwdriver into the upper section of the connection until the spring clamp opens in the 
lower section.  Insert the uninsulated wire, and remove the screwdriver causing the clamp to grab 
the wire.  

M3 User's Manual V 1.0 Revised 13, Sept 2011  

Page 7

 

Содержание M3

Страница 1: ...ITAL AUDIO PLAYER User s Manual Version 1 0 Revised 13 Sept 2011 Doc 99 20 088 25 00 MACKENZIE LABORATORIES INC 1163 Nicole Court Glendora CA 91740 USA Tel 909 394 9007 Fax 909 394 9411 Web www mackla...

Страница 2: ...ol lines 13 The unit must be securely attached to a wall board rack or table mounted Regulations FCC Part 15 Radio Frequency Interference The M3 generates and uses radio frequency energy and if not in...

Страница 3: ...mmands 14 4 1 System functional commands 14 4 2 System configuration commands 14 4 3 System description commands 14 4 4 Enhanced System commands 14 4 5 RS232 Command Syntax 15 4 5 1 Play snippet comma...

Страница 4: ...houses up to 4 M3 modules Must be ordered as a system not field upgradable Messages are stored on SD Card memory cards 1GB included Messages are randomly and instantly accessible Messages are stored a...

Страница 5: ...Voltage 12VDC 1 amp Connection 2 pin 3 81mm euro terminal Audio Data Formats Compressed MPEG 1 Layer III Rates mono 7kHz 32k bits per sec 15kHz 64k bits per sec 20kHz 128k bits per sec Control I O Con...

Страница 6: ...2 M3 1 1 Dual Balanced Stereo audio channels 10 message input selections each RS232 wall mount table top package Interfaces of M3 1 PLUS Channel 2 CH2 Left channel balanced audio output Right channel...

Страница 7: ...messages the memory will be shipped separately Refer to Section 5 for additional information on checking memory 8 Connect and apply power 9 Test unit operation 2 2 Configuration and Features M3 1 M3 1...

Страница 8: ...message playback Start 1 Connect to common for message 1 playback Start 2 Connect to common for message 2 playback Start 3 Connect to common for message 3 playback Start 4 Connect to common for messag...

Страница 9: ...e confusing to the listener Allowing a delay time can make the playback easier to understand Global setting for all messages 3 4 One second delay between plays Five second delay between plays Ten seco...

Страница 10: ...message queuing Message queuing allows the user to input multiple momentary activation s to the M3 causing each of the messages to be played in the order they were received The queue length will be 16...

Страница 11: ...ects a memory key with only an empty Upload folder and not other folders all audio files will be copied from the M3 into this folder on the memory key If both a Complete and a Delta folder exist on th...

Страница 12: ...stop message playback Start 1 Connect to common for message 1 playback Start 2 Connect to common for message 2 playback Start 3 Connect to common for message 3 playback Start 4 Connect to common for...

Страница 13: ...message 20 playback Com Connecting any input to common activates the function The Stop and Common inputs are parallel to the corresponding inputs on the 1 10 connector 3 AUDIO FILE FORMATTING The M3 u...

Страница 14: ...ow control The default baud rate is 115 200 The following commands are supported by the M3 system over this port 4 1 System functional commands Play snippet PLY I Stop playing STP ALL System reset RST...

Страница 15: ...tion for more details The PLY command can be suffixed with I making the command PLYI When this command is issued to a particular channel any currently playing message will be halted and the snippet sp...

Страница 16: ...Command body Filename Files can be written to the memory card The process is initiated using this command which after received places the system into a mode awaiting the start of a Y Modem download pr...

Страница 17: ...cognized the system will output Invalid value please re enter and the command will be ignored 4 5 8 Restore Default Configuration Command code CFG Command body none Any settings configured over the RS...

Страница 18: ...d by this setting Example DLY10 CR will set the delay time before a message play to 10 seconds Command response Delay time set to 10 seconds If the user enters DLY with out any suffix the system will...

Страница 19: ...mmand body a b a Snippet Number acceptable values any valid Snippet b Priority Level acceptable levels 0 to 1 default value 1 This command is basically a snippet enable disable command that can be exp...

Страница 20: ...e See above 4 5 16 Command Listing Command code LST Command body None Displays the list of all supported commands available to the user The response will be formatted in the following way System funct...

Страница 21: ...ace or a comma Example TIM 12 59AM CR will set the time to 12 59AM Command response Time set to 12 59AM If the user enters TIM with out any suffix the system will respond with the current setting Exam...

Страница 22: ...t provided in the command string the value will default to channel 1 Example TRE 3 1 CR will set the Bass to 3dB on channel 1 Example TRE 3 1 CR will set the Bass to 3dB on channel 1 Example TRE 3 2 C...

Страница 23: ...e memory card from the M3 4 Replace cover and secure with the four mounting screws 5 2 Installation 1 Unscrew the four mounting screws and remove the cover plate to expose the memory card holder 2 Ali...

Страница 24: ...gital Message repeaters are the ideal audio announcement solutions for Public Address Amusement Entertainment Museum and Exhibit applications Self contained solid state systems offer unparalleled reli...

Отзывы: