The boiler is
producing
excessive fumes
Presence of water in the fuel
tank
Empty the fuel tank and refill with
clean fuel.
The starter electrodes are
not positioned correctly
Check the distance of the electrodes
The fuel nozzle is dirty
Clean the fuel nozzle
The fuel nozzle has worn out
Replace the fuel nozzle
The boiler coil is blocked
Clean the boiler coil
The fuel pump is dirty
Clean the fuel pump
The fuel valve is not working
Replace the fuel valve
The boiler
switches itself off
The fuel tank is empty
Refill the fuel tank
The filter on the fuel suction
tube is dirty
Clean the fuel filter
Presence of water in the fuel
tank
Empty the fuel tank and refill with
clean fuel.
The transformer is broken
Replace the transformer
The electrodes are not
positioned correctly
Check the distance of the electrodes
The fuel nozzle is dirty
Clean the fuel nozzle
The fuel nozzle has worn out
Replace the fuel nozzle
The fuel pump is damaged
Replace the fuel pump
The fuel valve is damaged
Replace the fuel valve
Water is present
in the pump oil
Casing side seal rings are
worn out
Replace the seal ring
Gaskets are worn out
Replace the gaskets
Air being sucked in
Check that all pipes and hoses are
secure
Dirty water filter
Clean the water filter
Insufficient water supply
Ensure the water supply can supply
the minimum volume required
Noise
The springs on the suction
and/or delivery valves are
worn out or broken
Replace the valves
Foreign body caught in the
suction and/or delivery
valves
Check the valve and clean if needed
Worn out ball bearings
Replace the ball bearings
Worn out gaskets
Replace the gaskets
PROBLEM
CAUSE
SOLUTION