5
MACE
XCi
PRODUCT MANUAL -
SECTION A: THE XCI DEVICE
CONTENTS
CONTENTS
MACE
XCi
PRODUCT MANUAL -
SECTION A: THE XCI DEVICE
6
2.0
Introducing the XCi device
The XCi device is the central processing unit of the system and includes the
enclosure, battery and five card slots allowing the user to install any of the six
different FloSeries3 cards that control the sensors.
On the front of the XCi device, a backlit liquid crystal display (LCD) allows the
user an on-site readout of parameter values and status messages. Pressing
either membrane switch will turn on the LCD.
The membrane switches can be used to scroll the display between the
various parameters being measured.
A communications port is located on the bottom face of the main enclosure.
Using a MACE USB data cable (Part No. 850-363) between this port and a PC,
users can configure, troubleshoot and download data from the device using
the MACE FloCom
+
software downloadable from
www.macemeters.com
LCD Display
Secure Latch
with Padlock
Hole
Membrane Switches
(scrolls the display up & down)
XCi DEVICE - FRONT
NOTE: Door not shown
Conduit Cable Entry Point
Pole Cable Entry Point
12V Battery
Bracket
Charger Input
16-30VDC
(Centre of jack
is positive)
External Battery Input
12VDC
(Charged by XCi Device)
Solar Panel/Charger
Input 16-30VDC
(Use with Solar Panel
or Mains Plug Pack)
Communications Port
XCi DEVICE - INSIDE
XCi DEVICE - UNDERSIDE
Card Slots 1-5
Communications Port
Controller Module (slot 0)