background image

1   

     MACE

 

XCi 

PRODUCT MANUAL

CONTENTS

CONTENTS

     MACE

 

XCi 

PRODUCT MANUAL              

2

1.0

  Overview of the XCi system

This manual describes the installation, use and maintenance of a MACE XCi 

device. There are three MACE XCi devices which are specifically optimised for 

our three main markets:

The XCi system typically consists of five main components:

1.

   The XCi device

2.

   The solar panel (or power supply)

3.

   The sensor(s) or peripherals

4.

   Flocom

+

 software enabling you to configure and download data from your XCi device

5.

   FloSeries3 card(s) providing inputs for connecting an array of sensors

FloPro XCi 

Wastewater, stormwater and industrial flows

The FloPro XCi can be used to monitor just about any 

water quantity and quality sensor. Whether you need to 

measure flow as well as conductivity, pH and rainfall or 

utilize a downward looking ultrasonic depth sensor to 

measure pond levels the FloPro is fully expandable to 

your needs. Furthermore, FloPro is easily interfaced to 

SCADA/telemetry systems.

AgriFlo XCi 

Agricultural water and wastewater flows

The AgriFlo XCi can be used to monitor just about any 

agricultural sensor. Use the versatility of AgriFlo XCi 

to monitor inputs as diverse as: irrigation flows; farm 

wastewater flows; water quality; dam levels; soil moisture 

and engine management systems.

SENSORS/PERIPHERALS

SOLAR PANEL

XCi DEVICE

FLOCOM

+

 SOFTWARE

MACE Doppler Ultrasonic

Insert Velocity Sensor

MACE EchoFlo Ultrasonic

Depth Sensor

pH/DO/EC

Sensors

Rainfall Gauge

MACE Doppler Ultrasonic

Area/Velocity Sensor

Engine Controls

Wind Vane and 

Anemometer

MACE Doppler Ultrasonic

Velocity Sensor

Sonde

Water Sampler

Doppler Card

I/O Card

Pulse I/O Card

SDI-12 Master Card

WebComm Card

FloSI Card

FLOSERIES3 CARDS

MACE Electromagnetic

Insert Flow Sensor

HydroMace XCi 

Environmental monitor and data logger

The HydroMace XCi can be used to monitor just 

about any envornmental sensor. Use the versatility of 

HydroMace XCi to monitor inputs as diverse as: Flumes 

& weirs, water quality sensors & rainfall gauges, drinking 

water flows (leak detection) and weather stations.
The HydroMace XCi continues the long heritage 

established by MACE over 40 years ago for remote data 

logging and telemetry.

Содержание AgriFlo XCi

Страница 1: ...t MACE P L PO Box 911 Pennant Hills NSW 1715 Australia Ph 02 9658 1234 Fax 02 9651 7989 Email sales macemeters com www macemeters com Mace USA LLC PO Box 7144 Overland Park KS 66207 United States of A...

Страница 2: ...urn to the table of contents click on the Contents button at the bottom of each page Essential Reading Section A The XCi Device Section B Doppler Ultrasonic Velocity Sensors Only necessary if installi...

Страница 3: ...mission of Measuring Control Equipment P L Copyright 1996 2011 MACE P L All rights reserved Windows is a registered trademark of Microsoft Corporation in the United States and other countries WARNINGS...

Страница 4: ...s similar to switching on a flashlight in a fog Any reflective particle that moves within the beam will be seen by the ultrasonic sensor MACE Doppler ultrasonic velocity sensors provide a true averag...

Страница 5: ...alling on a wall 10 4 0 Installing XCi power options 11 4 1 Solar panel installation on a 2 pole 11 4 2 Installing a MACE mains powered trickle charger 13 4 3 Powering the XCi device with an external...

Страница 6: ...XCi Agricultural water and wastewater flows The AgriFlo XCi can be used to monitor just about any agricultural sensor Use the versatility of AgriFlo XCi to monitor inputs as diverse as irrigation flo...

Страница 7: ...3 MACE XCi PRODUCT MANUAL SECTION A THE XCI DEVICE CONTENTS CONTENTS MACE XCi PRODUCT MANUAL SECTION A THE XCI DEVICE 4 Section A The XCi device Installation powering maintenance...

Страница 8: ...etween the various parameters being measured A communications port is located on the bottom face of the main enclosure Using a MACE USB data cable Part No 850 363 between this port and a PC users can...

Страница 9: ...ACIDIC cure silicon sealant to the back of the XCi device in the channel around the cable entry point This will stop water flowing down the pole and into the XCi device 4 Use the two U bolts 3 8 nuts...

Страница 10: ...urely attached by tightening the thumb screws Ensure that the cable from the solar panel charger is terminated using the three pin connector provided in the electronics box and that the polarity is co...

Страница 11: ...the M8 bolts fits in the channel on either side of the solar panel Ensure that the gutter of the solar panel is positioned between the flat washer and the head of the M8 Bolt 6 Place the u bolt provid...

Страница 12: ...plugs directly into the XCi device See photos over page 4 1 Solar panel installation on a 2 pole Continued 2 Alternatively if a DC source other than a MACE charger is used this is terminated using the...

Страница 13: ...the new battery 1 Connect the battery cable to the new battery with the red lead to the positive terminal of the battery and the black lead to the negative terminal 2 Place the battery in the main en...

Отзывы: