![MacDonald Steel Limited HDP Deluxe DFC4 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/macdonald-steel-limited/hdp-deluxe-dfc4/hdp-deluxe-dfc4_manual_3192456024.webp)
MacDonald Steel Limited
BREWERY SYSTEMS DIVISION
24
REV 00
To use the RINSE CYCLE
Empty the beer manifold of as much product as possible (if full), by cycling the machine.
Connect a water line to the beer manifold.
Open the vent flow controls fully C.C.W.
Bring shuttles forward to start position.
Place bottles on shuttles.
Select CIP on display menu.
Set a rinse time between 10 to 99 seconds.
Push the “
Rinse
” button on the screen.
Follow on screen instructions for starting, canceling or exiting the cycle.
Cycle time can be monitored by staying on the CIP screen.
Connect Co2 to the beer manifold and run a short Rinse cycle to clear the water, just
before filling operation. Use the "
Purge
" buttons on the main screen to clear the Co2 lines
of water.
Note
MAXIMUM TEMPERATURE FOR HOSES IS 70
°°°°
F
To use the WASH CYCLE
Empty the beer manifold of as much product as possible (if full), by cycling the machine.
Connect the beer input and the Co2 input with the CIP jumper hose provided.
Connect a caustic line to the input of the jumper.
Open the vent flow controls fully C.C.W.
Bring shuttles forward to start position.
Place bottles on shuttles.
Select CIP on display menu.
Set a wash time between 1 to 30 minutes.
Push the “
Wash
” button on the screen.
Follow on screen instructions for starting, canceling or exiting the cycle.
Cycle time can be monitored by staying on the CIP screen.
When the caustic cleaning is completed, connect water to the input jumper and repeat the
above steps. Sanitizer can be used in the same way.
When finished turn off power, heads will stay down sealing the system.
To exit the CIP mode, hold the stop switch until the door opens.
Connect Co2 to the beer manifold and run a short Rinse cycle to clear the water, just
before filling operation. Use the "
Purge
" buttons on the main screen to clear the Co2
lines of water.
Note
MAXIMUM TEMPERATURE FOR HOSES IS 70
°°°°
F
When using the pressurized keg, be sure the keg does not empty before the wash time stops.
Typically, the drain hoses are gathered together and placed into an empty keg for collection of the
cleaning solution. The contents can then be transferred through the machine again.
Stopping the CIP WASH cycle also resets the wash timer, however the machine remains in the
CIP mode, to restart push the start switch. The CIP cycle repeats every 20 seconds, therefore
selecting several short wash times has no effect on the overall performance.