R2 Series Clinic Handout 17
M1240 Windrower
Break-in Inspection
The table below can be referenced in the M1240 Operator’s Manual
Inspection Interval
Item
Check
1 Hour
Drive wheel nuts
Torque: 510 Nm (375 lbf·ft) dry
Repeat checks at one hour intervals until torque stabilizes
at two consecutive checks
5 Hour
A/C compressor belt
Tension
5 Hour
Caster wheel nuts
Torque: 170 Nm (125 lbf·ft)
5 Hour
Caster wheel anti-shimmy dampener bolts
Inboard bolt torque: 136 Nm (100·lbf·ft)
Outboard bolt torque: 244 Nm (182 lbf·ft)
Outboard jam nut: 136 Nm (100 lbf·ft)
5 Hour
Walking beam width adjustment bolts
Torque: 759 Nm (560 lbf·ft)
10 Hour
Walking beam width adjustment bolts
Torque: 759 Nm (560 lbf·ft)
50 Hour
Drive wheel nuts
Torque: 510 Nm (375 lbf·ft) dry
Repeat checks at one hour intervals until torque stabilizes
at two consecutive checks
50 Hour
Hose clamps: air intake / radiator / heater / hydraulic
Hand-tighten unless otherwise noted
50 Hour
Walking beam width adjustment bolts
Torque: 759 Nm (560 lbf·ft)
50 Hour
Caster wheel nuts
Torque: 170 Nm (125 lbf·ft)
50 Hour
Caster wheel anti-shimmy dampener bolts
Inboard bolt torque: 136 Nm (100·lbf·ft)
Outboard bolt torque: 244 Nm (182 lbf·ft)
Outboard jam nut: 136 Nm (100 lbf·ft)
50 Hour
Engine gearbox oil
Change
50 Hour
Drive wheel lubricant
Change
50 Hour
Charge system oil filter
Change
Содержание R2 Series
Страница 1: ...R2 Series Clinic Handout...
Страница 20: ...MD 1000C2 R2 Series Clinic Handout 4 5 2020...