262175
215
Revision A
1027579
A
B
C
D
E
Figure 5.260: Hard Plumbed Connections on Disc
Header-Ready Windrower with Case Drain Kit
6.
Connect the hydraulic hoses to the windrower as follows:
a.
Connect rotary disc pressure hose (A) as shown and
torque it to 215 Nm (159 lbf·ft).
b.
Connect rotary disc return hose (B) as shown and
torque it to 215 Nm (159 lbf·ft).
c.
Connect case drain hose (C) to the mating 1/2 in.
coupler as shown.
NOTE:
The case drain hose coupler will be present only if the
Low Pressure Case Drain kit (B6698) has been installed.
IMPORTANT:
Ensure that the case drain hose is connected to
port (C),
NOT
port (E).
d.
Connect the electrical harness to receptacle (D).
1015478
A
B
Figure 5.261: Left Platform
7.
Push latch (A) to unlock platform (B).
1012700
A
Figure 5.262: Left Platform
8.
Pull platform (A) toward the cab until it stops and the latch
is engaged.
9.
Calibrate the header on the windrower. For instructions,
refer to
Содержание M2170