262175
177
Revision A
1030607
A
A
B
C
D
E
Figure 5.176: Header Hydraulic Fittings
7.
Connect the hydraulic fittings to the hydraulic hoses as
follows:
NOTE:
The two quick couplers and two elbow fittings are supplied
in the Quick Coupler kit (B6277).
a.
Attach 90° elbow fitting (A) and 1 in. female coupler
fitting (B) to disc pressure hose (C).
b.
Attach 90° elbow fitting (A) and 1 in. male coupler
fitting (D) to disc return hose (E).
1030596
A
B
C
D
E
F
Figure 5.177: Hydraulics and Electrical
–
Auger/Rotary
Disc/Draper-Ready Configuration
8.
Connect the hydraulic hoses to the windrower as follows:
a.
Connect disc pressure hose (A) to coupler (B).
b.
Connect disc return hose (C) to coupler (D).
c.
Connect case drain hose (E) to fitting (F) so that the
relief valve points toward the ground.
NOTE:
Loosen and tighten fitting (F) as needed to ensure that the
relief valve is pointing down.