4. Memories
Any picture on stage can be stored as a memory and recalled by touching a
button. If the actual position is created by recalling a preset, any modification
of this preset will cause the memory to recall the modified values. Therefore it
is no longer necessary to adjust every single scene when adapting programs
to a new stage setup.
4.1 Programming of basic memories
STORE button
The display shows a matrix with 16 columns for the
scans and 12 rows for the features. "-" in the matrix
indicates, that this feature is not available for the
registered scan. Small dots in the middle of a square
show, that the feature for this scan was set by the
encoder wheel, a cross indicates, that the value is a
presetvalue.
STORE MATRIX when
controlling 6 scans.
Preset values
Encoder values
Stage coordinates
For the beginning it is just
important, to have all
squares in the matrix
inverted.
(>> 4.3 SELECTIVE
MEMORIES)
Note: if the STORE
MATRIX is not completely
selected, only some of the
adjustments on stage are
stored.
(>> 4.3 Selective Memo-
ries)
During initial programming operations, all blocks within the matrix have to be
displayed in inverted contrast. In case some of the squares are not inverted,
press
1. x CLEAR button in the feature block
The matrix is cleared, all blocks are not displayed
inverted.
SCANSELECTION
Use -CLEAR - INVERT to select all scans
2. x CLEAR
The matrix is completely selected. All blocks are
displayed inverted.
The matrix is stored internally and reconstructed as soon as the next picture
is stored.
Selecting the complete
STORE MATRIX
SHUTT
IRIS
FOCUS
C-M-Y
PRISMA
COLOR
DIMMER
GOBO
MOVE
CIRCLE
SPEED
ROTAT.
EXTRA 1
EXTRA 2
SCAN No: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16