background image

R7F4HML3-D-DAC32A

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-8002-A  Rev.2  P. 3 / 12

 

POWER SUPPLY

Cable connector

: TFMC1,5/5-STF-3,5 (Phoenix Contact)

(included in the package)

Applicable wire size

: 0.2 − 1.5 mm

2

;  stripped length 10 mm

Recommended solderless terminal

• AI0,25-10YE  0.25 mm

2

  (Phoenix Contact) 

• AI0,34-10TQ  0.34 mm

2

  (Phoenix Contact) 

• AI0,5-10WH 

0.5 mm

2

  (Phoenix Contact) 

• AI0,75-10GY  0.75 mm

2

  (Phoenix Contact) 

• A1-10 

1.0 mm

2

  (Phoenix Contact) 

• A1,5-10 

1.5 mm

2

  (Phoenix Contact) 

1 2 3 4 5

1. FE

Functional Earth

2. NC

3. NC

4. +24V

Power Input (24V DC)

5. 0V

Power Input (0V)

 

TERMINAL ASSIGNMENTS

• I/O Connection

Recommended cable connector:  XG4M-4030 (OMRON)
The cable connector is not included in the package.

39

40

1

2

PIN 

No.

ID

FUNCTION

PIN 

No.

ID

FUNCTION

1

V+

External excitation

2

V+

External excitation

3

V–

Out. Common

4

V–

Out. Common

5

Y15 OUTPUT 15

6

Y7

OUTPUT 7

7

Y14 OUTPUT 14

8

Y6

OUTPUT 6

9

Y13 OUTPUT 13

10

Y5

OUTPUT 5

11

Y12 OUTPUT 12

12

Y4

OUTPUT 4

13

Y11 OUTPUT 11

14

Y3

OUTPUT 3

15

Y10 OUTPUT 10

16

Y2

OUTPUT 2

17

Y9

OUTPUT 9

18

Y1

OUTPUT 1

19

Y8

OUTPUT 8

20

Y0

OUTPUT 0

21

NC NC

22

NC NC

23 COM In. Common

24 COM In. Common

25

X15 INPUT 15

26

X7

INPUT 7

27

X14 INPUT 14

28

X6

INPUT 6

29

X13 INPUT 13

30

X5

INPUT 5

31

X12 INPUT 12

32

X4

INPUT 4

33

X11 INPUT 11

34

X3

INPUT 3

35

X10 INPUT 10

36

X2

INPUT 2

37

X9

INPUT 9

38

X1

INPUT 1

39

X8

INPUT 8

40

X0

INPUT 0

Содержание R7F4HML3-D-DAC32A

Страница 1: ...ational range as indicated below 24V DC rating 24V 10 approx 100mA GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and I O signal for safety Before you remove the...

Страница 2: ...NK III LNK1 is established LNK2 Green Turns on at MECHATROLINK III LNK2 is established STATION ADDRESS Station Address is selected between 03H and EFH in hexa decimal The SA1 switch determines the MSD...

Страница 3: ...5 0V Power Input 0V TERMINAL ASSIGNMENTS I O Connection Recommended cable connector XG4M 4030 OMRON The cable connector is not included in the package 39 40 1 2 PIN No ID FUNCTION PIN No ID FUNCTION 1...

Страница 4: ...unit from the DIN rail 1 3 2 DIN RAIL MOUNTING RIGHT ANGLE Mounting 1 Insert the longer DIN rail mounter slider until it clicks twice as shown below 1 2 Set the upper hook at the rear side of the unit...

Страница 5: ...201 Fax 81 6 6659 8510 E mail info m system co jp EM 8002 A Rev 2 P 5 12 TERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 115 4 53 55 2 17 75 2 95 123 4 8...

Страница 6: ...5 11 16 17 18 19 20 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 3 25 X0 COM X15 PNP Connection NPN Connection X0 COM V Y5 V V Y15 Y7 Y14 Y6 Y13 Y12 Y1 Y4 Y11 Y3 Y10 Y2 Y9 V Y8 X6 COM COM X15...

Страница 7: ...or warning command ALM_CLR 06H Clear alarm or warning command CONNECT 0EH Establish connection command DISCONNECT 0FH Release connection command Standard I O profile DATA_RWA 20H Transmit I O data NOP...

Страница 8: ...CMD_STAT 3 4 0000H 0000H Clear current alarm or warning Other than 0000H is not available 5 6 00H 00H Reserve CONNECT 0EH Starts communication with master station BYTE COMMAND RESPONSE REMARKS 0 CONN...

Страница 9: ...ent from the slave to the master are set in the response With output data read back CH0 IN LO CH0 data low 8 bits Bit 0 through 7 of input data are set CH0 IN HI CH0 data high 8 bits Bit 8 through 15...

Страница 10: ...LO CH2 data low 8 bits Not used CH2 OUT HI CH2 data high 8 bits Not used CH3 OUT LO CH3 data low 8 bits Not used CH3 OUT HI CH3 data high 8 bits Not used CMD_CTRL CMD_CTRL command area is following BI...

Страница 11: ...125 sec 17H Max Transmission Cycle 4 Yes 0x0061A800 64 msec 18H Increments of Transmission Cycle 4 Yes 0x00000001 Available to 31 25 62 5 125 250 500 sec 1 64 msec 1 msec increments 19H Min Communica...

Страница 12: ...9 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 8002 A Rev 2 P 12 12 I O DATA DESCRIPTION DISCRETE I O MODULE Input 0 Input 1 Input 2 Input 3 Input 15 Input 7 Input 8 Output 0 Output 1 Output...

Отзывы: