C MX 5710 Reference Manual. Rev 1.0
Page 31 of 36
Description: a textual explanation of the behavior of the individual
parameter.
You can use the “Filter” function (located above the actual list of parameters) to
show only a subset of the complete list, based on textual filtering. The filter will
actually search in any part of the parameter definition, including the parameter
code, the textual description and even the Current Value.
NOTE:
In theory, it would be possible to manage and monitor the complete
functionality of the module by accessing the relevant parameters on this
tab only. All the other tabs in the GUI are only provided to provide better
explanations and overview.
Parameters control everything
As stated in the previous chapter, the complete behavior of any LYNX Device
can be controlled and monitored with
the parameters listed on the “Params” tab.
All other parts of the LYNX APPolo Control System use exactly the same
parameters access and control the devices.
The LYNX CustomControl feature
connects the individual elements
of a custom-made Design to real
device parameters by their Code.
See http://appolo.lynx-
technik.com/ -> CustomControl for
details.
The LYNX AutoControl automation
rules access the individual
Parameters (for both Conditions
and Actions) by their Code.
See http://appolo.lynx-
technik.com/ -> AutoControl for
details.
The LYNX RemoteIF API addresses individual Parameters by Code.
See http://appolo.lynx-technik.com/ -> RemoteControl for details.
The LYNX SNMP Control provides one OID (numerical address in the
MIB) per individual Parameters. The exact mapping of Parameter Code to
OID is provided in the MIB files.
See http://appolo.lynx-technik.com/ -> RemoteControl for details.
Finding the Parameter Code name for a given Parameter in the graphical GUI is
made easy by clicking the Right-Mouse-Button onto the graphical control
an
ywhere in the GUI and then selecting the “Parameter Details” option (see
Figure 26: Parameter Details from GUI