C MX 5710 Reference Manual. Rev 1.0
Page 30 of 36
Additionally, these messages can be displayed in the APPolo GUI’s Event Log
(bottom part of the APPolo GUI, enabled from the “View” menu). This can,
however be disabled by
removing the checkboxes from the “Log in GUI” columns
(separately for “Event becomes Active” and “Event not active anymore”
messages.
Similarly, an SNMP trap can be generated from the APPolo Server for any
message in the APPolo Event System. Refer to the LYNX Remote Control Guide
for more information on SNMP (available from http://appolo.lynx-technik.com)
Parameters
The “Params” tab lists all available control parameters of the complete device.
Every switch and function in any other part of the GUI is actually just a graphical
control of a parameter listed on this page. There are, however, a number of
parameters for more detailed control that are only accessible in this list of
p
arameters on the “Params” tab.
All parameters are defined by the following aspects:
Code: This is a unique code to identify the parameter. The Code can
contain the slash-
character ‘/’, to provide some structure to the total
collection of parameters. The Parameter Code is always to be specified
as the complete text string (i.e. including all slashes).
Name: a human readable short parameter name, which is used as the
default text label in most parts of the GUI, as well as in any
CustomControl Panel.
Access: read-write or read-only accessibility. Note that for some
parameters, the accessibility status may potentially change, depending on
the current value of other parameters. E.g. the value of parameter A might
be controlled automatically by default, so the accessibility of A will be
displayed as “read-only”. But a boolean parameter B might be provided to
switch off the automatic behavior. So when parameter B is set to
MANUAL, then parameter A would dynamically change to “read-write”.
Current Value: This is the current value of the parameter. If Accessibility
is “read-write” (see above), then the Current Value can be modified.
Figure 25: Param Tab