background image

30

  

 

|

 

 

CARE & USE/INSTALLATION

LYNX LIMITED WARRANTY

I. Limited Five-Year Residential Warranty 

The stainless steel body housing is warranted to be free from 

defects in material and workmanship when subjected to 

normal domestic use and service for Five years from date of 

purchase. This warranty excludes surface corrosion, scratches, 

and discoloration which may occur during regular use. This 

warranty is limited to the replacement of the defective parts, 

with the owner paying all other costs including labor and 

shipping.

II. Limited One-Year Residential Warranty 

All other heater components are warranted to be free from 

defects in material and workmanship for a period of one 

year from the original date of purchase. Lynx will replace or 

repair parts found to be defective at no cost to the original 

purchaser.

III. Limited (90) Day Commercial Warranty

This warranty applies to commercial applications such as 

apartment buildings, restaurants, golf clubs and food service 

locations. Lynx will replace or repair parts found to be 

defective at no cost to the original purchaser within 90 days 

of the original date of purchase.

IV. Limitations & Exclusions

1.  This Warranty shall apply to products purchased and 

located in the United States and Canada.  Products must 

be purchased in the country where service is requested.

2.  Warranty applies only to the original purchaser and may 

not be transferred.

3.  Warranty is in lieu of all other warranties expressed or 

implied and all other obligations or liabilities related to 

the sale or use of its grill products.

4.  Warranty shall not apply and Lynx is not responsible 

for damage resulting from misuse, abuse, alteration 

of or tampering with the appliance, accident, hostile 

environment, flare-up fires, improper installation, or 

installation not in accordance with the instructions 

contained in this manual, or the local codes.

5.  Lynx shall not be liable for incidental, consequential, 

special or contingent damages resulting from its breach 

of this written warranty or any implied warranty.

6.  Some states do not allow limitations on how long an 

implied warranty lasts, or the exclusions of or limitations 

on consequential damages. This warranty gives you 

specific legal rights and you may have other rights which 

vary from state to state.

7.  No one has the authority to add to or vary Lynx’s 

warranty, or to create for Lynx any other obligation or 

liability in connection with the sale or use of its products.

8.  Limited to the replacement of defective parts with the 

owner paying all other costs including labor.

V.  What is not covered: Lynx shall not be responsible for 

and shall not pay for the following

1.  Installation or start-up, damages or problems caused by 

improper installation or use;

2.  Service by an unauthorized service provider;
3.  Damage or repair due to service by an unauthorized 

service provider or use of unauthorized parts;

4.  To correct normal adjustments or settings, due to 

improper installation, commissioning or local gas supply 

properties.

5.  Shipping and handling costs, export duties, installation, 

removal, or re-installation cost (RMA excluded).

6.  Display models are sold “as is”. If you have purchased 

a display model, please be advised that it is sold “as is” 

and that it is subject to the following warranty exclusions: 

any exterior or cosmetic damage is nonwarrantable; 

any missing components will be replaced at consumers 

expense; major handling damage to manifold, valve and 

ignition system will be serviced at consumer’s expense; all 

other warranties will remain in effect.

7.  The cost of a service call to diagnose complaint. 
8.  Modification  to  Lynx  product  will  void  related  warranties.                           

*

Содержание LHEM48

Страница 1: ...LYNX EAVEMOUNT HEATER LHEM48 CARE USE INSTALLATION MAKE THE MOST OF YOUR...

Страница 2: ......

Страница 3: ...will be subject to radiant heat and could be seriously damaged Gas heaters are not design certified for and are not to be installed in or on recreational vehicles portable trailers boats or any other...

Страница 4: ...e adequate ventilation when cooking IF YOU SMELL GAS 1 Shut off all gas supply lines to the heater 2 Extinguish any open flames 3 If odor continues keep everyone away from the heater and immediately c...

Страница 5: ...no odor If not installed operated and maintained in accordance with manufacturers instructions the emissions from this product can cause serious illness or death Never use this appliance in an enclose...

Страница 6: ...s Steel with welded construction Spark ignition with heat sensing safety pilot Slim custom profile Attractive and adjustable heavy duty mounting brackets extension is made from 6 GA 3 16 thick stainle...

Страница 7: ...preferred installation places the gas exit and vented valve access cover of the heater on the RIGHT side This position places the gas exit and the AC adaptor cord at the REAR of the heater installati...

Страница 8: ...be used in fire sprinkler systems where heaters are present as these substances may become flammable when heated A fire sprinkler professional must be consulted when heaters are installed where fire s...

Страница 9: ...must be NO CLOSER than 12 to a rear wall Use the LOWEST pair of holes in the mounting bracket extension arms See illustration below ANGLED MOUNTING If the heater is to be mounted at an angle up to 30...

Страница 10: ...ressure can affect overall heater performance Calculate the total BTU output of all equipment and refer to Gas Supply Line Runs for allowable run distances for inch pipe Failure to meet these minimum...

Страница 11: ...le pivot adjustment of the heater after installation has been complete GAS LINE PURGING You should purge the gas line of air before attempting to light the heater Slowly turn on the main gas supply Wi...

Страница 12: ...RANCE REQUIREMENTS MUST BE OBSERVED Each mounting bracket is provided with 4 mounting holes A quantity of 8 5 16 x 1 1 2 Stainless lag bolts have been provided for installation If mounting into solid...

Страница 13: ...from the house CAUTION DO NOT MOUNT HEATER FACING TOWARD the house This position would allow exhaust heat to be directed toward the combustible surfaces It is important to note that when mounting on a...

Страница 14: ...d then anchors will be needed follow instructions that come with the anchors If the mounting bracket is resting entirely on the wood surface mount using all 4 screws per bracket It mounting on the edg...

Страница 15: ...ter It is recommended that the gas line be securely fixed to the wall or mounting surface WARNING do not run gas line in a location that it can be tripped over or in a location that passes by either t...

Страница 16: ...em with new fittings Once again apply sealing compound around all joints and re assemble the pipes and fittings If a flexible gas line is being used to connect the heater to the hard piping and the le...

Страница 17: ...he heater It is recommended that this cord be secured to the wall or similar structure with either tape wire ties or insulated wire staples This installation is considered a TEMPORARY installation Sel...

Страница 18: ...ALLER of the 2 access plates The battery pack will be mounted directly inside on the endplate Using a small Philips head screwdriver remove the screw and slide off the battery box cover Replace or ins...

Страница 19: ...to hang below the heater it is connected to the battery wires Look inside the compartment and locate the black vinyl cover cap on the side of the module enclosure Peel the cap off with your finger na...

Страница 20: ...Gas NG installation turn the manual shut off valve lever turn so that the lever is parallel and in line with the gas line If this is a Liquid Propane LP installation open the gas cylinder valve by a...

Страница 21: ...Y AND TIME DISPLAY The current day of week and time of day will be continuously displayed in the TIME PROG Zone except during Setup operations The day of week will be displayed as one of the following...

Страница 22: ...N Zone Unused TIME PROG Zone AUX Zone Unused FLAME Zone DOWN Button MODE SET Button UP Button HEATER MODES OF OPERATION Operation modes MANUAL ON MANUAL OFF THERMOSTAT ON To cycle between modes in the...

Страница 23: ...switch is used to turn ON the heater it will always light on HIGH THERMOSTAT MODE Thermostat Mode will cycle heater on and off based on air set temperature seen directly at the remote control The rem...

Страница 24: ...e MANUAL OFF mode If the user turns the control back ON and the air temperature is still 95F degrees or greater the transmitter will switch back to MANUAL OFF THERMOSTAT DISABLE FEATURE If after using...

Страница 25: ...omatic functions thermostat program etc will continue normally To activate or deactivate the Child Lock feature press and hold the MODE SET and DOWN Buttons simultaneously for 5 seconds The system is...

Страница 26: ...ention of the and terminals Reinstall the battery box cover and secure it in place with the Philips head screw Reinstall the louvered end plate with the 2 screws and use caution not to pinch the batte...

Страница 27: ...still not light check the orifice and venturi for insects or blockage HEATER WILL LIGHT BUT PILOT AND BURNER CYCLE ON AND OFF REMOTE CONTROL FUNCTION If using the thermostat on the remote the SET tem...

Страница 28: ...ation then either the pilot burner the main burner or both have become wet The heater can be manually lit by following the instructions in the previous block There is also a remote control function th...

Страница 29: ...acturing engineers with over a century of collective experience had a dream They dared to take their extensive commercial manufacturing know how and create a line of outdoor cooking products that offe...

Страница 30: ...ent flare up fires improper installation or installation not in accordance with the instructions contained in this manual or the local codes 5 Lynx shall not be liable for incidental consequential spe...

Страница 31: ...CARE USE INSTALLATION 31 LYNX EAVE MOUNTED EXPLODED DIAGRAM...

Страница 32: ...8 NPT Fem 1 19 33337 Nipple Pipe 3 8 NPT x 2 1 2 1 20 13009 Elbow Ori ce w o Hood Pin 1 21 33505 Ori ce 36 Short IR NG 1 13016 Ori ce 50 LP 1 22 14014 Screw 8 32 x 3 8 THP SS 28 23 33930 Battery Hold...

Страница 33: ...Celsius 21 G Gas Connection Information 10 Gas Connections Making 15 Gas Leaks 16 Gas Pressure Taps 26 I Index 33 Initializing Remote 19 L Low Battery Indicator 25 M Mounting Considerations 7 Mountin...

Страница 34: ......

Страница 35: ......

Страница 36: ...The best outdoor kitchen products come from Lynx Grills Inc 7300 Flores Street Downey CA 90242 Service 888 289 5969 Fax 562 299 6978 www lynxgrills com PN 33535 Rev B 2018...

Отзывы: