CARE & USE/INSTALLATION
|
23
MANUAL OFF MODE
• Transmits heater OFF command.
• LCD Displays:
MODE Zone: OFF is displayed
ROOM /AIR TEMP Zone: Measured temperature is
displayed
SET TEMP Zone: Blank
TIME/PROG Zone: Current day indicator and cur
rent time is displayed
FLAME Zone: Blank
MANUAL ON MODE
• Transmits Heater ON command
• LCD Displays:
MODE Zone: ON is displayed
ROOM/AIR TEMP Zone: Measured temperature is
displayed
SET TEMP Zone: Blank
TIME/PROG Zone: Current day indicator and cur
rent time is displayed
FLAME Zone: the FLAME-‘A’ Icon is displayed
ADJUSTING THE HEAT LEVEL
During the MANUAL ON mode the heat level can be
adjusted up to 6 levels of heating increments when using
Natural Gas, and 3 levels for LP applications. To adjust
heat level, select “ON’ mode, and allow the heater to cycle
on. Press and hold flame level ‘A’ on the touch screen (the
larger flame icon) until the flame flashes. The current heat
level will be displayed #1 through #7. Press the UP arrow
button at the bottom to raise the heat level. Likewise, press
the DOWN arrow to LOWER the heat level. The heater
will immediately respond as the heat level is adjusted on
the remote control. NOTE: be sure that the LARGER flame
icon (labeled ‘A’) is selected when adjusting the heat level.
The smaller flame icon ‘B’ is not used for this adjustment.
Also NOTE: when using the touch screen remote, the
last heat setting used as the heater was turned off will be
remembered by the remote. As the heater is turned back
on, it will resume heating at the previous level. If the wall
switch is used to turn ON the heater, it will always light on
HIGH.
THERMOSTAT MODE
• Thermostat Mode will cycle heater on and off based
on air set temperature seen directly at the remote
control. The remote control will transmit the ON
command when SET TEMP is set 2 degrees higher
than AIR/ROOM TEMP, and will transmit OFF command
when SET TEMP becomes 2 degrees lower than ROOM
TEMP. These +/- 2 degrees are known as ‘swing
temperature’, and can be adjusted. (See SWING
temperature below).
• Built-in thermostat will measure air temperature.
• SET TEMP: While in THERMOSTAT mode, press the UP
or DOWN Button to change the SET TEMP (45-99 deg.
F, 7-37 deg. C); the new set temperature will automati-
cally be accepted after 2 seconds. NOTE: THERMO OFF
will be read in the upper MODE set window until the set
temperature is set to a level (2 degrees) higher than air
temperature (this is called SWING TEMPERATURE). Then,
this will change to THERMO ON.
• SWING Temperature:
• Factory default is 2 degrees F (1 deg. C).
• To change this 2 degree default, press and hold
the SET TEMP Zone for 5 seconds to enter SWING
Adjustment, and press the UP and DOWN Buttons
to adjust the SWING temperature from 3 degrees F
(2 degrees C) or to 1 deg. F (still 1 deg. C) (press the
MODE/SET Button or wait for 15 seconds for the new
setting to be accepted).
• LCD Display - When in SWING Adjustment:
MODE Zone: Blank
ROOM/AIR TEMP Zone: Blank
SET TEMP Zone: S1, S2, or S3 (number
equals swing temperature) in place of SET
temperature
TIME/PROG Zone: Blank
FLAME Zone: Blank
• THERMOSTAT OFF LCD Displays:
MODE Zone: THERMO and OFF is displayed
ROOM /AIR TEMP Zone: Measured temperature is
displayed
SET TEMP Zone: SET TEMP is displayed
Time of day is displayed
TOUCH SCREEN REMOTE CONTROL
...