INSTALLATION / USE & CARE
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length 3/4”
Pipe (in feet)
Max BTU for all
Appliances on line
10
360,000
20
245,000
30
198,000
40
169,000
50
150,000
60
135,000
70
123,000
80
115,000
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODEL-SPECIFIC BTU OUTPUTS
MODEL
ROTISSERIE (Btu)
TRIDENT™ (Btu)
TOTAL INPUT
LF36AT(F)R
1 @ 14,000
3@ 23,000
83,000 Btu/Hr