12
User can set speak limit time in this interface, when this function is on, system will start counting the
time if microphone is on and will close this microphone when the limit time is over.
Limit time range: 1-60 minutes
Warning time range: 1-60 seconds: the microphone led will start to flash when the remaining time reach
to the warning time range
c) Moderator setting (Menu A)
If system has more than 1 chairman microphone, user can set one of them as moderator, this chairman
microphone can control sign-in/ballot function.
d) Conference Mode (Menu A)
“Limit” mode (1-4): When this mode is selected, this display will show LIMIT MODE, plus the number of
delegates that can speak simultaneously. Once this number of delegates is reached, no further
delegates will be allowed to intervene until the number of active delegate microphones again falls below
this limit
“FIFO” mode (1-4): When this mode is selected(First In-First Out), the display will display FIFO MODE,
plus the number of delegates who can speak simultaneously. In this mode, the keeps track of the order
in which the delegate microphones are activated. Once the preset limit of simultaneous delegates has
been reached, and a new delegate presses the
MIC ON/OFF
key on his microphone, the FIRST
microphone that was active when this limit was reached will be made inactive, and the new delegate
microphone will be activated.
“Request” mode (1-4): When this mode is selected, only controlled by the software operator to decide
the request microphone on/off, there is no limitation of the request microphone number, but only 4
delegate microphone can be on maximum at the same time.
Chairman microphone is unlimited by conference mode,only controlled by itself or software.
e) Chairman only Mode (Menu A)