background image

 

10 

 
Canadian Fire Hearth Rigid Vent System 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Vent Installation 

• All Rigid vent sections and elbows utilize slip type joints. 
 
• Each joint should be secured by three screws. 
 
• High temperature sealant is recommended at the connection start of the 
venting on the appliance end. Use high-temperature silicone or Mill-
Pac©. 
 
• If for any reason the venting must be disassembled upon re-assembly 
all vent joints must create a tight fit. If in doubt apply high-temperature 
sealant to ill fitting sections. 
 
• Horizontal venting runs will require non-combustible supports such as 
metal strapping. Generally every six feet is preferable. 

 

• Co-Axial 2 ply flexible chimney liner must be secured to appliance 
with a minimum of three screws for both 5” exhaust and 8” air intake 
sections 
 
.• High temperature sealant is recommended at the connection start at 
the appliance. Use high temperature silicone or Mill-Pac©. 
 
• It is important to support lengths of flexible chimney liner with non 
combustible strapping at three foot intervals to prevent the venting 
system from dropping or sagging

. Failure to maintain a level or 

horizontal rise will lead to improper combustion and can be a 
safety hazard. 

2 Ply Flexible Chimney Liner supplied by CFH Mfg. 

24” minimum 

WTR58 
Wall Thimble 

Non-combustible 

Brick 

43” 
Minimum 

18.5” 

Содержание Riviera-42

Страница 1: ...uture reference Do not store or use gasoline or other Flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not t...

Страница 2: ...omponents Page 10 Vent Installation Page 11 Vertical Venting Page 12 Horizontal Venting Page 13 Exterior Vent Clearances Page 14 Installation Planning Page 15 Installing Non Combustible Panels Page 16...

Страница 3: ...uld have at least on fire extinguisher An approved Class A B C extinguisher should be mounted on the wall near an exit and close to the application but not so close that accessibility to the extinguis...

Страница 4: ...raffic areas Nothing should ever be placed on or near the surface of the fireplace including the top of the unit Clothing or other flammable material should not be placed on or near the appliance Make...

Страница 5: ...g Electrical Rating 115 volts 0 7 amp 60hz Steady State Efficiency 67 45 P 4 1 Annual Fireplace Efficiency 56 50 Circulating fan optional Variable Speed Vent System Direct Vent Glass Ceramic Clean Fac...

Страница 6: ...installed on the top of the opening Non combustible panel must be fastened to the top of any combustible framing 20 5 from floor or platform to the frame opening Is lowest acceptable measurement 24 t...

Страница 7: ...to the ceiling must not be less than the 43 inches dictated by the internal ceiling height Mantel sizes and clearance when applicable follow guideline described in this manual Mantel Requirements No...

Страница 8: ...to the appliance access to the gas compartment becomes limited A grounded 117volt AC line must be supplied to the appliance and wired into the electrical box which is fixed to the right hand side of t...

Страница 9: ...ng a separate solid fuel burning appliance Side Wall Co Axial termination without Nailing Flange V58 Side Wall Co Axial termination with Nail Flange RVF58 Vertical Co Axial Termination Simpson DuraVen...

Страница 10: ...supports such as metal strapping Generally every six feet is preferable Co Axial 2 ply flexible chimney liner must be secured to appliance with a minimum of three screws for both 5 exhaust and 8 air...

Страница 11: ...be either horizontal or vertical in any combination that does not exceed the four elbow limit All venting configurations that fall into the hatch area must have the 3 hole ring intake restrictor See p...

Страница 12: ...must have a minimum 4 foot rise Shortest run for Natural gas is one foot vertical and one foot horizontal Liquid Propane requires two 2 Feet minimum rise vertical one 1 foot horizontal Vinyl or Plast...

Страница 13: ...9 Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance K 1 83m 3 above if within 10 horizontally Clearance to mechanical air supply inlet L 2 13...

Страница 14: ...upply connection the fitter shall provide an easily accessible manual shut off valve The gas supply pipe should enter the appliance case through the opening at the right side The supply pipe should be...

Страница 15: ...ed only to avoid confusion The large 42 x34 25 inch front panel utilizes the cutout for installation under the appliance The 14 x 3 must be installed at the top of the wall opening when venting is rou...

Страница 16: ...for supporting the cover grille to be installed on completion A Power drill with Hex Nut driver should be used to attach surround as shown in Figure 2 Pre punched holes are provided Once the top has...

Страница 17: ...o secure it in place The Non combustible board can be fastened with standard drywall screws through the recessed holes provided when the appliance is ready to close in Figure 5 Figure 6 Install metal...

Страница 18: ...ce Do not use substitute materials Replacement of the panel should only be carried out by a licensed qualified service person Door Removal and Re Installation Instructions Window Re Installation To Re...

Страница 19: ...rical Schematic This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadi...

Страница 20: ...stat to lowest setting or on off switch to off 2 Turn off all electrical power to the appliance 3 Remove control access 4 Remove backup batteries if service is to be performed or for extended shutdown...

Страница 21: ...g s control and is not covered under warranty 1 Clean the glass regularly as soon as you notice the buildup white film If the film is left for a longer period of time build up will bake on Once baked...

Страница 22: ...tch MUST be rated for electronic Minimize splicing in all wiring and solder all unavoidable splices Thermostat Wire Information AWG mm ft m 22 0 6 10 3 0 20 0 8 25 7 6 18 1 0 40 12 2 16 1 3 64 19 5 14...

Страница 23: ...on glass Adjustment None Close damper Open damper Flame Quality Adjustment Access to this feature is done through the top of the burner cover by removing the two fasteners from the rectangular metal c...

Страница 24: ...ifice Danna Controls LPPO Main Burner Orifice Liquid Propane MB042LP Main Burner Orifice Natural Gas MBO42NG NON COMBUSTABILE COMPONENTS Front Panel 43 X 34 w Base Panel for under Riviera 42 FB001 Thr...

Страница 25: ...ponent Servicing Burner Removal First step is to remove the door Assembly refer to page 17 Once the door has been removed remove any decorative media that may be on the burner trays The rear baffle pa...

Страница 26: ...with respect to the Luxor Limited Lifetime Warranty CFHMfg may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the whol...