8
Corner Installation
15.25
68.00
50.49
A 45º angle installation
Installing Gas and Electrical Supply Lines.
Both Gas and Electrical lines must be installed and accessible for the installation of the Riviera 42.
Natural Gas requires a minimum inlet gas pressure of 5.0 in W.C.. Liquid Propane Fuel requires a
minimum of 11.0 in. W.C
. IMPORTANT:
Installer please allow a portion of the gas line
connecting to the appliance to be flexible enough for moving and aligning the appliance into the
chase. It’s very advisable to connect and secure gas lines before attaching the Cleanface Front.
After securing the Cleanface to the appliance access to the gas compartment becomes limited.
A grounded 117volt AC line must be supplied to the appliance and wired into the electrical box
which is fixed to the right hand side of the appliance. This will supply power to the AC Adapter
which powers the Electronic Valve System. and also provides power for an optional electrical
blower if installed.
Typical venting configuration for
corner installation
Framing and Clearance
Unit maybe installed in any location that maintains proper clearances to air conditioning ducts, electrical
wiring and plumbing. Safety, as well as efficiency of operation must be considered in selecting a fireplace
location. Select a location that does not interfere with room traffic, has adequate ventilation, and offers an
accessible pathway for venting installation.