background image

Open button

Status Indicator
LEDs

Open button

2

SQE-2

Status Indicator
LEDs

SQE-RL

SQE-3D

Open button
Close button

SQE-33

SQE-3E

Infrared
Receiver
Raise/Lower

Installation Instructions

Occupant Copy

Please read before installing.

CAUTION

!

Lutron recommends that Keypads be installed by a qualified electrician.

Do not connect high-voltage power to low-voltage terminals.

Improper wiring can result in personal injury or damage to

the control or to other equipment.

Keypads must be connected to the 

Sivoia QED

TM

Electronic Drive Unit (EDU) by using 

Class 2 (USA)/ PELV(IEC) wiring

methods.

Check with your local electrical inspector for the local code requirements and wiring practices

allowed in your area.

Use only a cloth with warm water and mild soap to clean faceplates (no chemical cleaners).

Keypad Configurations

Status Indicator
LEDs

Raise button
Lower button

Preset button
Close button

Raise/Lower

Status Indicator
LEDs

Preset button
Close button

1

2

3

Open button

Status Indicator
LEDs

Group Selection

LEDs

Preset button
Close button

Group 1 button
Group 2 button
Group 3 button

Содержание SQE-2

Страница 1: ...1 2 3 SQE 2 SQE RL SQE 3E SQE 3D SQE 33 Sivoia QED Euro style Keypads for use with Lutron Sivoia QEDTM Motorized Window Treatment System ...

Страница 2: ...ol or to other equipment Keypads must be connected to the Sivoia QEDTM Electronic Drive Unit EDU by using Class 2 USA PELV IEC wiring methods Check with your local electrical inspector for the local code requirements and wiring practices allowed in your area Use only a cloth with warm water and mild soap to clean faceplates no chemical cleaners Keypad Configurations Status Indicator LEDs Raise but...

Страница 3: ...on will cause the window treatments to stop Note Holding the or buttons for 5 seconds will cause the window treatments to move all the way open or closed automatically 3 Occupant Copy Installation Instructions Wiring Notes System Maximums Up to 96 devices total on one system One transformer per EDU The Keypads wire to the Sivoia QED Communication Link The Link can not exceed 1220 m 4000 ft total T...

Страница 4: ... Connector Sivoia QED EDU Back of Sivoia QED Keypad Installation Keypad circuits are classified as Class 2 circuits U S A and PELV circuits IEC When installing and wiring to these Keypads follow all applicable national and or local wiring regulations Warning Always turn Off the circuit breaker or remove the main fuse from the power line before doing any work Failure to do so can result in serious ...

Страница 5: ...icating the Keypad is in Programming mode 2 Initiate system addressing by tapping the Open button The LED next to the Open button will flash quickly 8 times a second and the LED next to the Close button will turn off The system is now being automatically addressed Press the Open and Close buttons simultaneously for 5 seconds Flashing once per second 3 Wait for system addressing to be completed Thi...

Страница 6: ... tapped an EDU will begin opening and closing over a range of approximately 200 mm 8 in Repeat tapping the Open button until the desired EDU is selected The Close button can also be used to select EDUs by moving through the EDUs in the opposite order 5 Store the current position as the Open limit by pressing and holding the Open button on the Keypad for 5 seconds The LED next to the Open button wi...

Страница 7: ...l move to their Open limit 4 Tap any button on an EDU to toggle between assignment or unassignment with the Keypad OR Use the Open button to step through each EDU in the system Each time the Open button is tapped a window treatment will begin opening and closing over approximately 200 mm 8 in Repeat tapping the Open button until the desired EDU is selected The Close button can also be used to sele...

Страница 8: ...ore of the following US patents 4 835 343 4 924 349 D422 567 D436 930 D453 742 D456 783 D461 782 D465 460 D465 770 D466 090 D466 091 D466 484 D475 024 D475 025 and corresponding foreign patents US and foreign patents pending Lutron the Sunburst logo and Sivoia are registered trademarks and Sivoia QED is a trademark of Lutron Electronics Co Inc 2005 Lutron Electronics Co Inc Note The current positi...