Sivoia QS Drapery System Installation Guide
7
Power Up the Drapery and Assign a Control
7.1 Initial Power-Up:
Connect the power supply to an appropriate power source.
The LED on the EDU will flash a red/green/blue pattern as
the EDU powers up.
7.2 Wireless Control Assignment:
7.2A
7.2B
A. Place the Drapery Drive in Assignment Mode.
•
Press and hold the open limit button on the drive until the green LED
flashes, then remains solid.
•
Tap an arrow
button on the drive. The green LED’s on the drive, and on
the wireless receiver, will flash twice every 4 seconds. The drive is now ready
to be assigned to a control.
•
Repeat the above steps for any other drapery drives that are being assigned
to the same control.
B. Complete the Assignment.
•
Press and hold the Close button on the wireless control for 6 seconds.
The drapery will move a short distance in each direction, or “wiggle” one
time. This confirms the drive has been assigned to the control, and exits
Assignment Mode.
C. Repeat steps 7.2A and 7.2B to assign more drapery drives and/or additional
controls.
NOTE:
Drapery systems can be assigned to multiple controls. To un-assign
devices, see “Restoring Factory Default Settings” on page 10.
For detailed system wiring, programming, and troubleshooting
information, please refer to P/N 045314 Sivoia QS Wiring &
Programming Guide.
To find the meaning of LED blink codes, see:
lutron.com/TechnicalDocumentLibrary/Sivoia QS Shades.html
8
Setting Open and Close Limits
A. Enter Limit-Set Mode
•
To set the close limit, tap the Close button.
The green LED illuminates.
•
To set the open limit, tap the Open button.
The green LED illuminates.
B. Move the drapery
•
Press and hold an arrow
or
button until the drapery is at the
desired location.
C. Press and hold the same button originally tapped in step 8.2A until the
green LED flashes, then turns off.
HOLD
TAP
HOLD
(6 sec)
Wall-Mounted
Hand-Held
TAP
Set Open Limit
HOLD
OR
Set Close Limit
TAP
OR
HOLD
A
C