Recess-Mount
IMPORTANT:
A drapery track with recess-mount brackets must be installed into a structural member using wood screws. Ensure
the structural member is of sufficient strength to support the combined weight of the drapery track, EDU, and fabric.
If no appropriate structural member is available at the mounting location, it is the responsibility of the installer to add blocking
as necessary to safely support the operating load of the system, including tugging that may occur during manual or attempted
manual operation.
3.1 Prepare the drapery track for mounting:
The drapery track is pre-drilled with mounting holes spaced as indicated below:
A. Insert a recess-mount bracket into the track’s upper channel.
B. Align its center hole with a mounting hole in the drapery track. Temporarily insert a mounting screw through both holes to maintain
their alignment.
C. Rotate the recess-mount bracket 90°.
D. Secure the recess-mount bracket using the
3
⁄
32
in Allen key provided to tighten both set screws.
Remove the mounting screw from the center hole.
E. Repeat steps 3.1A through 3.1D to install a recess-
mount bracket at each mounting hole location along
the entire length of the drapery track.
3.2 Mount the drapery track:
A. Position the drapery track in the desired location.
B. Insert the 1½ inch wood screw provided through the hole in the track
and recessed mounting bracket, and into a structural member in the
ceiling, as shown.
IMPORTANT:
The drapery track must be fully supported by at least two
people until all of the mounting screws are installed.
C. Repeat for all mounting holes in the drapery track
NOTE:
Ensure the pocket dimensions allow sufficient clearance for fabric
movement and stackback throughout the operating range of the system.
*The wood screws provided are appropriate for driving into
wooden structural members only. It is the responsibility of the
installer to select and install fasteners that are appropriate for
the supporting structure.
1½ inch Wood
Screw*
Structural
Member
Recessed
Recessed
Mounting
Bracket
Drapery
Track
2
1
⁄
4
inch (57 mm)
Minimum
Pocket Width
1
1
⁄
16
inch (27 mm)
Minimum
Pocket Depth
Top View
Track
Upper Channel
7.25 in
(184 mm)
7.375 in
(187 mm)
11 in (279 mm)
16 in (406 mm)
16 in (406 mm)