![Lutron Electronics Sivoia QS Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/lutron-electronics/sivoia-qs/sivoia-qs_installation-manual_1950794007.webp)
Sivoia QS Drapery System Installation Guide
Page 7
6
Ripplefold Fabric Installation
6.1 Drapery Panel Height
Drapes are typically sized so the bottom of the drapery track and top of the drapery panel are located 4 in (101 mm) above
the window casing. Location may need to be adjusted to accommodate the specific drapery panel height and application. It is
recommended that a space of 1⁄2-1 in (13-25 mm) be maintained between the bottom of drapery panel and the floor.
6.2 Attach the Drapery Panel
A. Attach a pendant to each male auxiliary snap on the drape, leaving 3
at each end open for attachment to the drive/idler snap bracket and/
or the master carrier.
B. Hang the pendant in the corresponding auxiliary carrier as shown.
C. Fasten the remaining snaps (3 at each end) to the drive/idler
snap brackets and master carrier(s) according to the drapery
configuration, following the appropriate configuration example below.
1
⁄
2
in (13 mm)
3
⁄
4
in (19 mm)
Floor
Snap Tape
Drapery Panel
Drapery Track
1
⁄
2
-1 in (13-25 mm)
Bottom of
drapery panel
Drapery
panel
height
+
3
⁄
4
-1
1
⁄
4
in
(19-32 mm)
Mounted Drapery Track
Pendant
Auxiliary Carrier
To Male Snap
on Drape
6.3 Configurations
Center draw, butt-closure
Idler-end Snap Bracket
Auxiliary snap locations
Drive-end snap bracket
Center-draw, butt-closure Master Carriers
One-way draw Master Carrier
Auxiliary snap locations
Drive-end snap bracket
One-way draw