Reserve power:

When the battery is completely discharged (all 5 red LEDs 

blink with a red backlight on), the light will shut down after 

flashing a few times. To activate the battery’s reserve power, 

doubleclick the switch. This will give you a few minutes 

more light, whose exact amount depends on the age of your 

battery. The light emitted in reserve-power mode is a very low 

beam so as to conserve power and keep the light going as 

long as possible. The red 5 LEDs slowly flash when reservepo-

wer mode is activated and the backlight will be red. 

When the 

reserve power has been completely discharged, the light will 

shut down – so be careful.

Note:  

When operating the lamp only with 

2 W or less

, no reserve power will 

be available.

Warning:

  

Do not switch on the light when the battery is  

discharged, as this will invariably 

damage the battery.

  

Recharge the battery as soon as possible to avoid a deep 

discharged battery. 

Reserve power

Содержание betty TL2 pro

Страница 1: ...1 BEDIENUNGSANLEITUNG OWNERS MANUAL Betty TL2 Pro Betty TL2 Pro ...

Страница 2: ...Pflege Lagerung 15 Fehlerbehebung 16 Technische Daten 17 Letzte Hinweise 18 Read this manual before using 19 Charging and installation 20 21 Operation 22 25 Programming 26 27 Special functions 28 29 Accessoires 30 Product care and storage 32 Troubleshooting 33 Technical data 34 Miscellaneous 35 Inhaltsverzeichnis Index Deutsch English ...

Страница 3: ...zt werden Die Lampe erfüllt die IP68 Schutzklasse ist jedoch keine Taucherlampe und für die Benutzung unter Wasser NICHT geeignet Verriegelung Entnahme der Lampe Vor der Entnahme der Lampe prüfen Sie ob die Sicherung geöffnet oder geschlossen ist Sowohl bei der Entnahme und dem Einsetzen der Lampe muss ein deutlicher Druckpunkt überwunden werden Warnung Niemals absichtlich den Lichtstrahl in die e...

Страница 4: ...r Zündung geladen wird um eine Entladung der Fahrzeugbatterie zu vermeiden Vor den Arbeiten am Netz unbedingt die Stromversorgung unterbre chen Das Ladegerät am Ende des Akkutanks erkennt automatisch die anliegende Spannung 12 24V Gleichspan nung Montage an der Wand oder im Fahrzeug Zur Befestigung der Docking Station nutzen Sie die Löcher in der eloxierten Metallschiene Wir empfehlen die Verwendu...

Страница 5: ... Widerstand überwunden werden Seien Sie nicht zögerlich die Ladestation ist solide konstruiert 3 Der Ladevorgang startet automatisch die LEDs blinken grün Ist der Akku voll leuchten die LEDs konstant grün Alternative Ladebuchse für Charger One Microcharger und Wiesel Lader Laden über die interne Ladebuchse Alternativ kann die Betty TL2 Pro auch mit vielen Lupine Standardladern geladen werden 1 Ste...

Страница 6: ...rzu Über 8 0 V ist voll Zwischen 7 1 und 7 9 V Akku nachladen Zwischen 6 5 und 7 V nicht einsatzbereit Hinweis Diese Anzeige können Sie jederzeit durch das Anschalten der Lampe unterbrechen Sie müssen also nicht die gesamte Anzeige abwarten bevor Ihre Lampe einsatzbereit ist Die Steuerelektronik misst die Spannung unter Last deshalb sind Messungen mit einem Voltmeter nicht vergleichbar Beispiel Di...

Страница 7: ...uck notwendig Die genaue Bedeutung der LED Anzeige wird anschaulich auf S 10 dargestellt dort wird auch erklärt wie man den werksseitigen 3 Stufen Modus verändern kann Hinweis Die zentrale rote LED wird nur in einem speziellen Leuchtmodus aktiviert ansonst leuchten nur die 6 äußeren LEDs Durch anhaltenden Tastendruck länger als 1 Sekunde schalten Sie die Lampe aus Entnommene Kapazität aus dem Akku...

Страница 8: ...leuchtung des Lampenkopfes durch blau grün oder rot angezeigt Sinkt die Akkuspannung unter bestimmte Werte dann wechselt das Licht von blau auf grün und kurz vor Ende der Kapazität auf rot Hinweis Bei permanenter Nutzung der starken Leistungsstufen können die Akkuleerwarnungen in sehr rascher Folge ablaufen Akku Warnanzeige geringe Restkapazität sehr geringe Restkapazität rot rot blinkend Akku lee...

Страница 9: ... schwaches Abblendlicht zu Verfügung Zur Anzeige des aktivierten Reservetanks blinken die 5 roten LEDs langsam und das Backlight leuchtet rot Bei dann vollständig entleertem Akku wird der Scheinwerfer zwangsweise abgeschaltet Hinweis Bei der ausschließlichen Nutzung mit 2 W oder weniger steht der Reservetank nicht mehr zur Verfügung Warnung Ein erneutes Anschalten ist nicht mehr möglich bzw nur du...

Страница 10: ...45 W Leuchtstufe 22 W Leuchtstufe SOS 2 W Leuchtstufe 8 W Leuchtstufe 34 W Leuchtstufe 16 W Leuchtstufe Center 0 8W 28 W Leuchtstufe Flash Werkseinstellung Nach dem Loslassen startet die Leucht stufenauswahl wieder automatisch Nun können sie die 2 Leuchtstufe festlegen Erfolgt keine Auswahl so leuchtet die Lampe mit nur einer Stufe Drückt man zum gewünschten Zeitpunkt sind 2 Leuchtstu fen festgele...

Страница 11: ...rale LED der Taschenlampe und erzeugt ein schwaches rotes Licht während die sechs äußeren LEDs deaktiviert werden SOS Die Lampe gibt bis zur Erschöpfung des Akkus oder Tastendruck ein SOS Signal Verwenden Sie es entsprechend umsichtig und nur in wirklichen Notfällen Die missbräuchliche Verwendung ist strafbar Polizeimodus Spezialmodus Im Polizeimodus leuchtet die Taschenlampe nur bei gedrücktem Ta...

Страница 12: ...llung Akku Kapazität grob einstellen z B für einen 6 6 Ah Akku 7 Ah wählen Tastendruck Ab sofort zeigt der Lampenkopf nährungsweise nach jedem Tastendruck den Zustand des Akkus mit den roten LEDs an Das Prinzip gleicht dem unserer Smartcore Akkus Dabei gilt eine dauerhafte leuchtende LED steht für einen 20 Schritt eine blinkende LED für einen 10 Schritt Achtung Wird der Akkutank vom Lampenkopf get...

Страница 13: ... solange gedrückt halten bis drei grüne LEDs leuchten Taster loslassen 2 1 Werkseinstellung 6 0 V 5 6 V 5 2 V 6 2 V 5 8 V 5 3 V 6 4 V 6 0 V 5 4 V 6 6 V 6 2 V 5 5 V 6 8 V 6 4 V 5 6 V Backlight blau rot grün 2 Rücksetzen auf Werkseinstellung Taste solange gedrückt halten bis fünf rote LEDs leuchten Taster loslassen 1 Im Anschluss müssen Sie den Lampenkopf einmal vom Akku trennen und alle Werkseinste...

Страница 14: ...ältlich sind aufgeschraubt werden Hinweis Filter nicht im Lieferumfang enthalten Der Adapter erlaubt die Montage der Lampe an einem Fotostativ Der Halter wird mit den beigefüg ten Schrauben an der Lampe befestigt Der Größe der Lampe geschuldet sorgen Sie für ausreichend stabiles Stativ 1 4 Zoll Adapter Art Nr 892 Diffusor Diffusor für Fotografie ...

Страница 15: ...rauch der Elektronik fördert ansonsten die vorzeitige Entladung des Akkus Weiterhin besteht die Gefahr dass die Lampe versehentlich eingeschaltet wird Die unkontrollierte Erwärmung könnte einen Brand verursachen oder anliegendes Kunststoffmaterial zum Schmelzen bringen Lagerung Vor längerem Nichtgebrauch laden Sie den Akku voll und lassen Sie ihn am Ladegerät angeschlossen Wählen Sie zur Lagerung ...

Страница 16: ...Die Lampe lässt sich nicht aus der Docking Station entnehmen Die Halterung scheint zu blo ckieren Ursache Tiefentladener Akku Akku nicht oder fehlerhaft mit Scheinwerfer verbunden LED Einsatz ist defekt Der Akku ist leer Der Akku ist alt Sehr tiefe Temperaturen Das Ladegerät ist defekt Polizeimodus aktiviert Sicherungshebel Behebung Akku laden Taschenlampe vollständig zudrehen Austauschen Laden Au...

Страница 17: ...tzeiten können abhängig von Alter Pflegezustand und Temperatur Schwankungen unterliegen Werkseinstellung 45 W 5000 Lumen 34 W 3900 Lumen 28 W 3200 Lumen 22 W 2650 Lumen 16 W 2050 Lumen 12 W 1550 Lumen 8 W 1050 Lumen 3 W 380 Lumen 2 W 270 Lumen 0 3 W 30 Lumen 0 8 W Center LED Lichtleistung Leuchtzeiten Betty TL2 Pro 1 Std 30 Min 2 Std 2 Std 30 Min 3 Std 15 Min 4 Std 30 Min 6 Std 9 Std 24 Std 36 Std...

Страница 18: ...n ANSI Messverfahren 30 Sekunden nach dem Einschalten Die Verwendung dieses Beleuchtungssystems für bestimmte Zwecke kann in Europa von Land zu Land unterschiedlich geregelt sein Informieren Sie sich über die in Ihrem Land gültigen Bestimmungen Innerhalb der Garantiezeit von 24 Monaten umfasst die Gewährleistung alle Komponenten und deckt fertigungsbedingte Mängel ab Ausgenommen ist jedoch der Akk...

Страница 19: ...re con ditions The lamp complies with IP 68 protection class but is NOT a diving lamp and is NOT suitable for use under water Locking mechanism Before removing the flashlight check the position of the lock Make sure the lock is open To remove or insert the flashlight into the docking station you must overcome a clear pressure point Safety instructions Warning Avoid looking directly into the light ...

Страница 20: ...ed 12V adapter 12V cable and cigarette lighter socket Through the internal socket and a Lupine standard charger not included Direct connection to 12V 24V DC through the included cable Hint We recommend you to setup the connection from an experienced vehicle builder or electrician It is advisa ble to design the system in a way it is only charging when the ignition is switched on in order to avoid d...

Страница 21: ...t 3 Charging starts automatically the LEDs flash green When the battery is full the LEDs light green Alternative charging socket for Charger One Microcharger and Wiesel Charge via the internal charging socket Alternatively the Betty TL2 Pro can also be charged with many Lupine standard chargers 1 Plug the charger into your wall outlet 2 Unscrew the rechargeable battery from the flashlight and the ...

Страница 22: ...ltage display More than 8 0 V the battery is fully charged 7 1 to 7 9 V the battery needs charging 6 5 to 7 V the battery is not ready for use Note To deactivate this display simply press the button In other words you needn t let the display go through its whole cycle in order to use the lamp The control electronics measures the voltage under load Thus measurements using a voltmeter will not be co...

Страница 23: ... When you shut off the lamp the discharged battery capacity is shown via flashing of the blue LED and then the green LED This information can only be displayed once as it is deleted when you unplug the battery The blue LED blinks once for each Ah ampere hour and then the green LED blinks once for each 1 10 of an Ah The ambient temperature and the use of high power levels can reduce power to the LE...

Страница 24: ...change color to indicate decreasing voltage When battery voltage drops below a certain level the Backlight LED changes from blue to green Near the end of the battery s charge the light turns red Note When permanently operating the lamp at high power the battery warnings may be issued in very quick sequence Battery warning low capacity remaining very low capacity remaining red red blinking battery ...

Страница 25: ...ve power mode is a very low beam so as to conserve power and keep the light going as long as possible The red 5 LEDs slowly flash when reservepo wer mode is activated and the backlight will be red When the reserve power has been completely discharged the light will shut down so be careful Note When operating the lamp only with 2 W or less no reserve power will be available Warning Do not switch on...

Страница 26: ...s lvl 12 W brightness lvl 45 W brightness lvl 22 W brightness lvl SOS 2 W brightness lvl 8 W brightness lvl 34 W brightness lvl 16 W brightness lvl center 0 8W 28 W brightness lvl flash Default setting Upon releasing the button the sequence of brightness levels automatically restarts al lowing you to set a second level in the same manner as the first click set up This process can be repeated up to...

Страница 27: ... Useful for anybody who wants to avoid that the lamp is switched on accidentally in particular during transport e g in a backpack The light will continue with SOS until the battery is empty Use it carefully and only in case of a real emergency Due to the lamp s high light output this signal is visible for several miles the opera ting time is several hours Misuse may be prosecuted Stealth Center Do...

Страница 28: ...lly 3 Ah 5 Ah 7 Ah 9 Ah 4 Ah 6 Ah Disable indicator 8 Ah 10 Ah Default setting You must approximate the correct range for your battery e g for an 6 6Ah you would select 7 Ah 5 green LEDs Similair to our Smartcore batteries the red LEDs on the lamphead will now approxi matley show the remaining capacity Attention When the lamp head is discon nected from a battery the indicator will not work correct...

Страница 29: ...below Press and hold the button until 3 green LEDs light up release the button 2 1 Default setting 6 0 V 5 6 V 5 2 V 6 2 V 5 8 V 5 3 V 6 4 V 6 0 V 5 4 V 6 6 V 6 2 V 5 5 V 6 8 V 6 4 V 5 6 V Backlight blue red green 2 Recover factory settings Press and hold the button until 5 red LEDs turn on release the button 1 Disconnect the battery and all factory settings will be restored ...

Страница 30: ... available as foto accessories can be used Note Filters are not supplied with the light The adapter allows to mount the light on a tripod Use the screws which came with the adapter to connect it to the light According to the long batte rytank we recommand a stable tripod 1 4 Inch Adapter Art No 892 Diffusor Diffusor for camera ...

Страница 31: ...m the lamp Otherwise the small amount of power used by the electronics will discharge the battery Furthermore the lamp may be switched on accidentally The uncontrolled heat buildup could cause a fire or melt adjacent plastic material Storage When the lamp will not be used for a longer period of time fully charge the battery and leave it connected to the charger Choose a cool dry place for storage ...

Страница 32: ...k if I keep the button pressed The docking station mechanism seems to be blocked Cause Deep discharged battery Battery not or not properly connected to the light head Faulty LED unit Faulty LED unit Discharged battery Old battery Very low temperatures Faulty charger Police mode enabled Lock not fully opened Solution Charge the battery Properly screw on the flash light head Replace the LED unit Cha...

Страница 33: ... TL2 Pro 7 h Betty TL2 Pro 9 9 Ah ORC 72Wh 7 2 V Li Ion Terminals 3 hardgold plated bronze parts Current 1 5 A max Battery life may vary depending on battery age condition and temperature Light Output Battery life Betty TL2 Pro 1 h 30 min 2 h 2 h 30 min 3 h 15 min 4 h 30 min 6 h 9 h 24 h 36 h 240 h 90 h 45 W 5000 Lumens 34 W 3900 Lumens 28 W 3200 Lumens 22 W 2650 Lumens 16 W 2050 Lumens 12 W 1550 ...

Страница 34: ...ents as well as any manufacturing defect The warranty does not include the battery however In addition any modification or improper use of the product will void the warranty Warranty Lumen lm Lumens Unit of luminous flux Usually differentiated in measured and cal culated values Calculated values often differ considerably from the actual light output Our lumen values are measured in our own calibra...

Страница 35: ...35 Betty TL2 Pro Deutsch Purchase date Dealer stamp Notizen Notes ...

Страница 36: ...36 Betty TL2 Pro Lupine Lighting Systems GmbH Winnberger Weg 11 92318 Neumarkt Germany Phone 49 0 91 81 50 94 90 Fax 49 0 91 81 50 94 915 E mail info lupine de www lupine de ...