background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

User Manual

 

Содержание Megta Strobe FX12

Страница 1: ...User Manual ...

Страница 2: ...ntation 9 Rigging 9 4 Operation 10 Control Panel Operation 10 Menu Map 10 Configuration DMX 11 Starting Address 11 DMX Channel Modes Assignments and Values 12 2 Channel 12 5 Channel 12 8 Channel 12 Configuration Standalone 13 Sound Active Mode and Sound Sensitivity 13 Automatic Mode 13 Automatic Program Brightness and Strobe Speed 13 Temperature Display 13 Display Orientation 13 Load Factory Defau...

Страница 3: ... which only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the product or ...

Страница 4: ...ake sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no venti...

Страница 5: ...MegaStrobe FX12 User Manual Rev 2 Page 5 of 18 2 INTRODUCTION Overview Back Panel View DMX Out DMX In Power In LED Display and Control Buttons Fuse Holder Microphone Power Out ...

Страница 6: ...Page 6 of 18 MegaStrobe FX12 User Manual Rev 2 Dimensions 3 9 in 98 mm 6 7 in 171 mm 13 8 in 350 mm ...

Страница 7: ...ect the product to a protected circuit circuit breaker or fuse Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire Never connect the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement Disconnect the product from power before replacing the fuse 1 Disconne...

Страница 8: ...egaStrobe FX12 units on 120 VAC or up to 48 MegaStrobe FX12 units on 230 VAC The power linking diagram shown above corresponds to the North American version of the product ONLY If using the product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may differ in your country or region 1 st Product 2 nd Product 3 rd Product Additional P...

Страница 9: ...ely to a rigging point such as an elevated platform or a truss When rigging the product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has 13 mm holes which are appropriate for this purpose When power linking multiple products you must always consider the length of the power linking cable and mount the products close enough for the cable to reach The bracke...

Страница 10: ...ected value Menu Map Main Level Programming Levels Description Starting Address d___ d001 d512 Selects the DMX starting address DMX Personality _CH 2CH Selects the DMX personality 5CH 8CH Auto Program Brightness and Strobe Speed C000 C000 C255 FS 0 FS 9 Sets the auto program brightness and strobe speed Automatic Mode AUtO Sets auto program Sound Active Mode and Sensitivity SU SU 0 SU 8 S 00 S 99 S...

Страница 11: ...MegaStrobe FX12 uses up to 8 DMX channels in its 8 channel DMX mode which defines the highest configurable address to 505 If unfamiliar with DMX download the DMX Primer from www chauvetlighting com To select the starting address do the following 1 Press MENU repeatedly until d001 d512 shows on the display 2 Press ENTER 3 Use UP or DOWN to select the starting address 4 Press ENTER DMX Personalities...

Страница 12: ...ff 237 ó 255 Shutter 3 Shutter Speed 000 ó 255 0 to 100 when Ch 2 is 033 255 Sound sensitivity when Ch 2 is 016 032 4 Pixels 000 ó 255 Pixel control 000 ó 255 Auto program speed when Ch 5 is 049 240 000 ó 255 Sound sensitivity when Ch 5 is 241 255 5 Auto Programs 000 ó 048 No function 049 ó 064 Auto program 1 065 ó 080 Auto program 2 081 ó 096 Auto program 3 097 ó 112 Auto program 4 113 ó 128 Auto...

Страница 13: ... mode follow the instructions below 1 Press MENU repeatedly until AUtO shows on the display 2 Press ENTER Automatic Program Brightness and Strobe Speed To set the automatic program brightness and strobe speed do the following 1 Press MENU repeatedly until C000 C255 auto program brightness shows on the display 2 Use UP or DOWN to select the desired brightness 3 Press ENTER 4 User UP or DOWN to sele...

Страница 14: ...ntil SLAV shows on the display 2 Press ENTER to accept 3 Connect the DMX input of the first slave unit to the DMX output of the master unit 4 Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit 5 Finish setting and connecting all the slave units Master unit 1 Set the master unit to operate in either Automatic or Sound Active mode 2 Make the master unit ...

Страница 15: ... room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface and vents 4 Clean all external optics and glass transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue 6 Softly wipe any dirt or grime to the outside ...

Страница 16: ...A Power linking current units 8 A 26 units 8 A 48 units Fuse F 2 A 250 V F 2 A 250 V Power I O US Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Power Lifespan LED 3 W 50 000 hours Color Quantity Current White 12 700 mA Photo Optic Parameter Illuminance 2 m 2186 lx Beam angle 20º Field angle 38º Strobe rate...

Страница 17: ... prepared to provide the model number serial number and a brief description of the cause for the return You must send the merchandise prepaid in its original box and with its original packing and accessories CHAUVET will not issue call tags Clearly label the package with the RMA number CHAUVET will refuse any product returned without an RMA number Write the RMA number on a properly affixed label D...

Страница 18: ...n Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO CHAUVET Mexico General Information Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexico C P 52000 Voice 52 728 285 5000 Technical Support Email servicio chauvet com mx...