manualshive.com logo in svg
background image

The model name, unique 4- or 5- digit serial number and 
certification markings of the light engine are carried on a 
label a

xed to the rear panel.  Performance specifications 

for individual light engines are listed on the certificate of 
conformance included with the shipping documents e-
mailed to the customer (Figure 1).

3.2  Installation 

NOTE: Any end-product/system incorporating or coupled 
to a Lumencor Light Engine shall be fully evaluated to 
verify all applicable safety and regulatory compliance 
requirements prior to use. 

When setting the RETRA (L) Light Engine up for use, place 
the unit on a hard surface and avoid blocking or restricting 
airflow at the air inlet (front panel; Figure 3) or exhaust 
ports (rear panel) on the enclosure.  Restricting the airflow 
will cause the unit to operate at elevated temperatures and 
will result in decreased product life and/or premature 
failure.  

The RETRA (L) Light Engine must be operated in a non-
condensing environment (dew point <10ºC with controlled 
ambient temperature <30º C). Thermal overload protection 
is provided by the on-board computer in conjunction with 
an on-board temperature sensor.  If the internal 
temperature registered by the sensor exceeds 50°C 

OR

 the 

fan rotor is stopped, all light output channels automatically 
turn OFF and are locked in this state until the internal 
temperature is below 50°C and/or the fan restarts.  The 
current reading of the on-board temperature sensor is 
displayed on the front panel status display (Figure 3) and in 
the GUI (Figure 5).

Connect the DC power supply to a grounded AC wall outlet 
using the power cord supplied with the light engine.  
Connect the DC output to the 6-pin receptacle on the front 

RETRA (L) Light Engine Manual 57-10025

10

lumencor.com

Figure 3. 

 RETRA (L) Light Engine front panel.

Figure 4. 

 AURA (L) Light Engine rear panel.

Remote 
interlock
connector (with 
jumper installed)

Содержание RETRA

Страница 1: ...Lumencor Light Engine Manual RETRA L Light Engine RETRA L Light Engine Manual 57 10025 1 lumencor com...

Страница 2: ...ification IEC EN 60825 1 2014 Safety of laser products CE Marking Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU RoHS Directive 2011 65 EU 2015 863 EU REACH Regulation EC No 1907 2006 EC EU...

Страница 3: ...ons and Warnings 3 Installation and Operating Instructions 4 Light Output Characteristics 5 Operational Specifications 6 Routine Maintenance and Trouble Shooting 7 Customer Support 8 Warranty RETRA L...

Страница 4: ...ht output and generates a reference signal that is applied to the constituent sources in a feedback loop to maintain constant light output over time The light sources within the RETRA L Light Engine a...

Страница 5: ...ssement d clarations qui identifient des situations ou des pratiques susceptibles d entra ner des blessures corporelles Caution Statements identify conditions or practices that could result in damage...

Страница 6: ...te s curit dans un chemin optique ferm NE PAS pointer la sortie de lumi re directement sur un mat riau susceptible d tre inflammable ou susceptible de br ler Cela comprend tous les tissus les plastiqu...

Страница 7: ...nal control and laser aperture that can be separated by 2m or more from a radiation warning device shall itself be provided with a radiation warning device Do not exceed 2m without providing a radiati...

Страница 8: ...ss optical components that could be damaged or misaligned by the shock produced by a drop onto a hard surface Attention NE PAS laisser tomber la source lumineuse Elle contient des composants optiques...

Страница 9: ...k jumper Figure 2 6 Quickstart Guide instruction document 85 10049 RETRA L Light Engine Manual 57 10025 9 lumencor com AC Power Cords Region Part Number North America 29 10002 Europe 29 10005 United K...

Страница 10: ...in decreased product life and or premature failure The RETRA L Light Engine must be operated in a non condensing environment dew point 10 C with controlled ambient temperature 30 C Thermal overload pr...

Страница 11: ...tion Initialization of the onboard computer takes about 30 seconds after the master power switch is turned on When initialization is complete the status indicator display Figure 3 will activate The Ke...

Страница 12: ...DISTANCE PEUT ENTRA NER UN COMPORTEMENT ANOMAL ET OU ENDOMMAGER LES PRODUITS WARNING Prior to turning the light output on be sure the output end of the liquid light guide or optical fiber is safely d...

Страница 13: ...terminated optical fiber connect the fiber to the output adapter using the integral threaded sleeve 2 To enable light output of the RETRA L Light Engine the external gate jumper control key remote int...

Страница 14: ...etting Tab right 10 Standby mode is also marked by an automatic shut o of the main cooling fan Standby mode automatically terminates when the next light output ON command is issued Output power regula...

Страница 15: ...e command set gives access to an extensive panel of operating status reports and configuration settings in addition to the the basic control functions of the LEGACY command set A complete listing of S...

Страница 16: ...utton next to TTL inputs in the GUI under the Settings tab Figure 5 Settings Tab right 12 or send the standard mode command SET TTLENABLE to the LAN port Input TTL signals can be conveniently addresse...

Страница 17: ...ificates of conformance are also recorded in Lumencor s database and copies can be requested by e mail to techsupport lumencor com The request message must include the 4 or 5 digit serial number of th...

Страница 18: ...the OFF state No light output in response to source ON command serial or TTL There are 4 interlocks that need to be closed check all of these 1 Control key must be inserted in front panel and turned t...

Страница 19: ...ns consistent with the specifications given in Section 5 and observing all the Precautions and Warnings notified in Section 2 This warranty does not extend to light engines that have been subject to m...

Страница 20: ...RETRA L Light Engine Manual 57 10025 20...

Отзывы: