background image

Regulatory Models 

Lumencor utilizes regulatory model names for all certified and CE marked products. The regulatory model names are 
traceable to all regulatory documentation, third party reports and certifications. 

Regulatory Model: Retra III L

” is used as a representative model for all certified and CE marked RETRA (L) laser products. 

Emissions 

This equipment has been tested and found to comply with the limits of EMC directive 2014/30/EU and FCC part 15 (CISPR 
11:+A1:2016). These limits are designed to provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. 

Safety Certifications 

TUV SUD America, CB Certification (IEC 61010-1:2010) 
TUV SUD America, NRTLus Certification (UL 61010-1:2012-05) 
TUV SUD America, cNRTL Certification (CAN/CSA-C22.2 No. 61010-1:2012)  
TUV SUD America, EN Certification (EN 61010-1:2010) 
Underwriters Laboratories (UL), CB Certification (IEC/EN 60825-1:2014 Safety of laser products) 

CE Marking 

Low Voltage Directive (2014/35/EU) 
EMC Directive (2014/30/EU) 
RoHS Directive (2011/65/EU+2015/863/EU) 
REACH Regulation (EC) No. (1907/2006/EC) 

EU Declarations of Conformity can be found at  

https://lumencor.com/company/compliance

 

For EU customers discarding end-of-life Lumencor electrical and electronic equipment: Please submit an RMA request with 
“Recycle product under WEEE” in the Description of Issues field. 

For disposal in countries outside of the European Union: This symbol is only valid in the European Union (EU). If you wish to 
discard this product, please contact your local authorities or dealer and ask for the correct method of disposal. 

Lumencor, Inc.

 |

 

14940 NW Greenbrier Parkway | Beaverton, OR 97006 USA | 503.213.4269 | 

www.lumencor.com

Revision D

011822

RETRA (L) Light Engine Manual 57-10025

2

lumencor.com

Lumencor Light Engines as supplied, and as represented in this manual, meet safety and regulatory requirements

 

For 

Research Use Only.

 

 If the light engine is incorporated into an instrument or system for a specific end-use application, 

it is the responsibility of the system integrator to verify that the light engine, and the system into which it is 
incorporated, meet all safety and regulatory requirements of that end-use application.

Содержание RETRA

Страница 1: ...Lumencor Light Engine Manual RETRA L Light Engine RETRA L Light Engine Manual 57 10025 1 lumencor com...

Страница 2: ...ification IEC EN 60825 1 2014 Safety of laser products CE Marking Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU RoHS Directive 2011 65 EU 2015 863 EU REACH Regulation EC No 1907 2006 EC EU...

Страница 3: ...ons and Warnings 3 Installation and Operating Instructions 4 Light Output Characteristics 5 Operational Specifications 6 Routine Maintenance and Trouble Shooting 7 Customer Support 8 Warranty RETRA L...

Страница 4: ...ht output and generates a reference signal that is applied to the constituent sources in a feedback loop to maintain constant light output over time The light sources within the RETRA L Light Engine a...

Страница 5: ...ssement d clarations qui identifient des situations ou des pratiques susceptibles d entra ner des blessures corporelles Caution Statements identify conditions or practices that could result in damage...

Страница 6: ...te s curit dans un chemin optique ferm NE PAS pointer la sortie de lumi re directement sur un mat riau susceptible d tre inflammable ou susceptible de br ler Cela comprend tous les tissus les plastiqu...

Страница 7: ...nal control and laser aperture that can be separated by 2m or more from a radiation warning device shall itself be provided with a radiation warning device Do not exceed 2m without providing a radiati...

Страница 8: ...ss optical components that could be damaged or misaligned by the shock produced by a drop onto a hard surface Attention NE PAS laisser tomber la source lumineuse Elle contient des composants optiques...

Страница 9: ...k jumper Figure 2 6 Quickstart Guide instruction document 85 10049 RETRA L Light Engine Manual 57 10025 9 lumencor com AC Power Cords Region Part Number North America 29 10002 Europe 29 10005 United K...

Страница 10: ...in decreased product life and or premature failure The RETRA L Light Engine must be operated in a non condensing environment dew point 10 C with controlled ambient temperature 30 C Thermal overload pr...

Страница 11: ...tion Initialization of the onboard computer takes about 30 seconds after the master power switch is turned on When initialization is complete the status indicator display Figure 3 will activate The Ke...

Страница 12: ...DISTANCE PEUT ENTRA NER UN COMPORTEMENT ANOMAL ET OU ENDOMMAGER LES PRODUITS WARNING Prior to turning the light output on be sure the output end of the liquid light guide or optical fiber is safely d...

Страница 13: ...terminated optical fiber connect the fiber to the output adapter using the integral threaded sleeve 2 To enable light output of the RETRA L Light Engine the external gate jumper control key remote int...

Страница 14: ...etting Tab right 10 Standby mode is also marked by an automatic shut o of the main cooling fan Standby mode automatically terminates when the next light output ON command is issued Output power regula...

Страница 15: ...e command set gives access to an extensive panel of operating status reports and configuration settings in addition to the the basic control functions of the LEGACY command set A complete listing of S...

Страница 16: ...utton next to TTL inputs in the GUI under the Settings tab Figure 5 Settings Tab right 12 or send the standard mode command SET TTLENABLE to the LAN port Input TTL signals can be conveniently addresse...

Страница 17: ...ificates of conformance are also recorded in Lumencor s database and copies can be requested by e mail to techsupport lumencor com The request message must include the 4 or 5 digit serial number of th...

Страница 18: ...the OFF state No light output in response to source ON command serial or TTL There are 4 interlocks that need to be closed check all of these 1 Control key must be inserted in front panel and turned t...

Страница 19: ...ns consistent with the specifications given in Section 5 and observing all the Precautions and Warnings notified in Section 2 This warranty does not extend to light engines that have been subject to m...