Operating Manual V8.2/03.2017
Non Invasive Road Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
25
Fig. 10: New
Adjustment
11 Sensor Adjustment
An adjustment is required during commissioning in order to correctly adapt the sensor to the
conditions at the installation location.
Note: Please refer to the conditions and instructions on page 24.
11.1 Readjustment using the UMB Config Tool
In sensor selection, select a NIRS31-UMB with associated ID (ID 1 in this example):
Check the sensor in the list with a mouse click and select
the ‘Configure’ function.
In sensor configuration
, now select the ‘Load profile from sensor’ function.
Select the
‘NIRS-UMB’ tab and in ‘Device parameters’ check ‘renew Adaption’:
In the ‘Main’ tab, now select the ‘store profile on sensor’ function.
The sensor automatically commences the adjustment after a restart.
11.2 Adjustment during Operation
The adjustment is checked permanently during operation and adjusted automatically, where
appropriate, for example to compensate for changes to the asphalt due to deterioration.