19.5.4.1 Buffer assignment Basic Data Set
Device configured for measurement values in metric units:
Measurement value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Water film height
600
0.0
2000.0
µm
Ice percentage
800
0.0
100.0
%
Road condition
900
0
Dry
1
Damp
2
Wet
3
Ice
4
Snow / ice
5
Chemically wet
6
Critically wet
8
Snow
99
Undefined
Buffer ‘1’
Road surface temperature
100
-40.0
70.0
°C
Freezing temperature (NaCl)
110
-40.0
70.0
°C
Buffer ‘2’
Snow height
610
0.0
10.0
mm
Saline concentration NaCl
810
0.0
100.0
%
Buffer ‘3’
Friction
820
0.0
1.0
Road Weather Index
910
0, 1, 2
Code
Device configured for measurement values in US units:
Measurement value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Water film height
600
0.0
2000.0
µm
Ice percentage
800
0.0
100.0
%
Road condition
900
0
Dry
1
Damp
2
Wet
3
Ice
4
Snow / ice
5
Chemically wet
6
Critically wet
8
Snow
99
Undefined
Buffer ‘1’
Road surface temperature
101
-40.0
150.0
°F
Freezing temperature (NaCl)
111
-40.0
32.0
°F
Buffer ‘2’
Snow height
610
0.0
10.0
mm
Saline concentration NaCl
810
0.0
100.0
%
Buffer ‘3’
Friction
820
0.0
1.0
Road Weather Index
910
0, 1, 2
Code