A-4
MAX TNT Hardware Installation Guide
Slot Card Specifications and Connection Information
DS3-ATM card
Table A-2 explains the DS3-ATM card status lights.
Connecting the DS3-ATM card to the WAN
Use two 75-ohm coaxial cables (RG 59/U) to connect the T3 line to the LINE RX and LINE
TX ports on the DS3-ATM card.
Inform your service provider that the equipment is connected, so the provider can activate the
line.
Connecting redundant DS3-ATM cards
You can install two DS3-ATM cards to provide redundancy. After installing the cards,
configure line profiles for each card as explained in the APX 8000/MAX TNT/DSLTNT
Physical Interface Configuration Guide.
Figure A-2 illustrates a redundant connection.
Figure A-2. DS3-ATM redundant configuration
Table A-2. DS3-ATM card status lights
Light
Color
Description
LA
Green
On indicates the DS3 interface is enabled and has not detected any
error conditions.
RA
Red
On indicates the DS3 interface is experiencing loss of receive
signal.
LF
Red
On indicates the DS3 interface is out of frame alignment.
YA
Yellow
On indicates the DS3 interface has detected Far End Receive
Failure indication transmitted from the other side.
AD
Yellow
On indicates the DS3 interface has detected an upstream equipment
fault.
FAULT Yellow
Behaves
as
follows:
•
Illuminated when the unit has been reset.
•
Goes out after the unit passes its power-on self test (POST) and
is running.
•
Blinks if a fatal error has occurred.