background image

2-6

MAX TNT Hardware Installation Guide

Preparing for Installation
Understanding the shelf-controller back panel

Status lights on the shelf-controller back panel

The status lights (also called LEDs) on the MAX TNT back panel can be helpful if you 
experience a problem, especially if it occurs shortly after power on. Figure 2-4 shows the 
location of the status lights on the back panel and Table 2-2 describes them.

Figure 2-4.  Location of the MAX TNT status lights

Table 2-2. MAX TNT status lights

Light

Color

Description

1

Green

On when the unit has power.

2

Green

On for any functioning shelf in a multishelf system, whether it is 
configured as master or slave.

3

Yellow

Behaves as follows:

Illuminated when you restart the unit

Goes out after the unit passes its power-on self test (POST) and is 
running

Blinks if a fatal error has occurred

4

Yellow

This is the multishelf alarm light. If the master shelf stops operating, this 
light illuminates on each slave shelf for about 9 seconds. It does not 
illuminate on the master shelf during a multishelf alarm condition.

5

Green

On when power supply A is installed and working.

6

Green

On when power supply B is installed and working.

7

Yellow

On when power supply A is installed and a fault occurs.

8

Yellow

On when power supply B is installed and a fault occurs.

9

Green

On when an Ethernet 10BaseT link has been established.

10

Green

On when an Ethernet AUI link has been established.

11

Green

On when the Ethernet link is active.

Содержание MAX TNT

Страница 1: ...MAX TNT Hardware Installation Guide Part Number 7820 0546 006 For software version 9 0 January 2001...

Страница 2: ...ks and trade names mentioned in this publication belong to their respective owners Copyrights for Third Party Software Included in Lucent Access Networks Software Products C Standard Template Library...

Страница 3: ...ftware version Software and hardware options If supplied by your carrier service profile identifiers SPIDs associated with your line Your local telephone company s switch type and operating mode such...

Страница 4: ......

Страница 5: ...ts on the shelf controller back panel 2 6 Chapter 3 Installing a MAX TNT Chassis 3 1 Guidelines for installing units in a rack or cabinet 3 1 Rack mounting a MAX TNT unit 3 2 Installing a MAX TNT exha...

Страница 6: ...ons A 16 Status lights A 16 Hybrid Access cards A 17 MultiDSP cards A 18 48 port MultDSP card A 18 96 port MultiDSP card A 18 OC3 ATM card A 20 PCTFI card A 22 Specifications A 22 Status lights A 22 C...

Страница 7: ...to WAN B 15 RS 449 cable to WAN B 17 Serial WAN cable B 18 IDSL cable specifications B 20 ADSL cable specifications B 25 SDSL cable specifications B 27 Appendix C Safety Related Electrical Physical a...

Страница 8: ......

Страница 9: ...sence of a PCMCIA card in slot 1 3 13 Figure 3 15 Identifying long medium and short lock screws 3 16 Figure 3 16 Inserting a slot card into a MAX TNT chassis 3 16 Figure 3 17 Lock screw and jack screw...

Страница 10: ...B 6 RJ 48C RJ 48C crossover cable B 10 Figure B 7 RJ 48C RJ 48C straight through cable B 11 Figure B 8 RJ 48C DA 15 straight through cable B 12 Figure B 9 RJ 48C DA crossover cable B 13 Figure B 10 R...

Страница 11: ...II and Series56 III digital modem card specifications A 24 Table A 19 STM 0 card specifications A 25 Table A 20 STM 0 card status lights A 26 Table A 21 SWAN card specifications A 27 Table A 22 T1 ca...

Страница 12: ...B 15 Table B 17 RS 449 cable pinouts B 17 Table B 18 Serial WAN cable pinouts B 18 Table B 19 IDSL cable pinouts B 20 Table B 20 ADSL cable pinouts B 25 Table B 21 SDSL cable pinouts B 27 Table B 22 C...

Страница 13: ...unning True Access Operating System TAOS software version 8 0 2 or later Some features might not be available with earlier versions or specialty loads of the software Warning Before installing your MA...

Страница 14: ...onal argument you might add to a command To include such an argument type only the information inside the brackets Do not type the brackets unless they appear in bold face Separates command choices th...

Страница 15: ...ng System 7 SS7 environment This guide explains shelf controller redundancy for an APX 8000 unit Configuration APX 8000 MAX TNT ATM Configuration Guide Describes how to configure Asynchronous Transfer...

Страница 16: ...ce to RADIUS attributes Administration APX 8000 MAX TNT Administration Guide Describes how to administer a TAOS unit including how to monitor the system and cards troubleshoot the unit and configure t...

Страница 17: ...ons and analog and digital transmission The unit complies with existing standards for networks authentication and Simple Network Management Protocol SNMP management Following is a summary of the MAX T...

Страница 18: ...d two power supply bays The backplane contains multiple buses that interconnect all slots MAX TNT supported slot cards Table 1 1 lists the slot cards supported on a MAX TNT unit and identifies the por...

Страница 19: ...ized OC 3 port Serial WAN SWAN 6Mbps to 8Mbps Four V 35 ports Series56 II Digital Modem 56Kbps 48 ports Series56 III Digital Modem 56Kbps 48 ports Synchronous Transport Module 0 STM 0 51 85Mbps One fi...

Страница 20: ......

Страница 21: ...roduct Before you install a MAX TNT unit make sure you have the following A suitable location with adequate power At least one active T1 or E1 line set up for bidirectional calling Bidirectional calli...

Страница 22: ...the unit to the Ethernet network Blank single slot filler cards for any unused slots in the unit Checking the package contents MAX TNT package contents vary depending on the base unit and slot cards...

Страница 23: ...requirements You can rack mount a MAX TNT unit in a standard equipment cabinet with a width of 19 or 23 inches 48 26cm or 58 42cm or place it on a flat surface as a free standing unit For more inform...

Страница 24: ...el of a MAX TNT unit The shelf controller is always slot 17 The remaining slots are numbered 1 through 16 For information about installing a slot card in a slot see Chapter 3 Installing a MAX TNT Chas...

Страница 25: ...re 2 3 shows the location and Table 2 1 describes the function of each element on the shelf controller Figure 2 3 MAX TNT shelf controller back panel Table 2 1 Description of shelf controller back pan...

Страница 26: ...gured as master or slave 3 Yellow Behaves as follows Illuminated when you restart the unit Goes out after the unit passes its power on self test POST and is running Blinks if a fatal error has occurre...

Страница 27: ...e Installation Guide 2 7 12 Green On when the Ethernet link is active and link integrity has been confirmed 13 Green On when there is Ethernet activity between MAX TNT shelves 14 Yellow On when an Eth...

Страница 28: ......

Страница 29: ...information specific to your product Guidelines for installing units in a rack or cabinet Keep the following information in mind when installing MAX TNT units in a rack or cabinet You must install an...

Страница 30: ...he operating ambient temperature of the rack environment might be greater than room ambient temperatures In enclosed racks make sure that openings exist in the floor underneath each cabinet to allow t...

Страница 31: ...allation Gulide 3 3 Figure 3 1 Installing the MAX TNT rack ears You can mount a MAX TNT unit in a 19 inch or 23 inch 48 26cm or 58 42cm rack A single MAX TNT shelf has the dimensions shown in Figure 3...

Страница 32: ...3 4 MAX TNT Hardware Installation Gulide Installing a MAX TNT Chassis Rack mounting a MAX TNT unit Figure 3 2 MAX TNT dimensions 11 5 17 4 14 0...

Страница 33: ...rack proceed as follows 1 Using a mechanical lift recommended or a minimum of two installers raise the unit to the proper height for installation 2 Insert the unit in the rack and secure it as shown i...

Страница 34: ...nstall an exhaust shield on a rack mounted MAX TNT unit The exhaust shield redirects hot air from the unit so that it is not being blown into adjacent units Figure 3 4 illustrates how to install the e...

Страница 35: ...output power supply cannot be used in redundant configurations with existing power supplies Attempting to mix and match different power supplies will invalidate associated warranties The high output...

Страница 36: ...supply To install a high output power supply proceed as follows 1 Power down the unit if necessary For ac power supplies unplug the power cord For dc power supplies remove dc power from the source 2 I...

Страница 37: ...output power supplies MAX TNT Hardware Installation Gulide 3 9 4 Remove the existing power supplies as shown in Figure 3 8 Figure 3 8 Removing the power supply 5 Gently insert the new power supply as...

Страница 38: ...g a plug that has a grounding pin This is a safety feature Equipment grounding is vital to ensure safe operation Do not defeat the purpose of the grounding type plug by modifying the plug or using an...

Страница 39: ...power supply switch is in the Off down position Installing live wires wires connected to a power source is hazardous Figure 3 11 Connecting to dc power Connecting a workstation to the serial port To...

Страница 40: ...marily for out of band management over the network and is not intended to support heavy traffic loads If your MAX TNT will be routing heavy Ethernet traffic install an Ethernet card and route this tra...

Страница 41: ...AM NVRAM and each flash card provides its own additional memory Make sure a PCMCIA card is inserted in the top PCMCIA slot identified as PCMCIA 1 in Figure 3 14 Caution Do not remove a PCMCIA flash ca...

Страница 42: ...connected with a straight through serial cable and is using the settings listed in step 2 of Connecting a workstation to the serial port on page 3 12 TNT unconfigured unit The system date is Thu Aug 2...

Страница 43: ...ticular slot card and for upgrade instructions see the release notes For information about loading software on the MAX TNT unit and recovering from a failed slot card installation see the APX 8000 MAX...

Страница 44: ...rt lock screws Installing a long lock screw slot card To install a long lock screw slot card in the MAX TNT chassis proceed as follows 1 Hold the slot card so that the panel is facing you and the lock...

Страница 45: ...half turn so that the slot card panel is free to allow the lock screw on the left side to self align 6 Using a number 2 Phillips screwdriver tighten the lock screw on the left side of the card 7 Fini...

Страница 46: ...TNT slot cards are hot swappable which means that you can safely insert or remove cards while power is on Note Be sure to install blank single slot filler cards in any unused slots to ensure proper a...

Страница 47: ...guration information see the APX 8000 MAX TNT Physical Interface Configuration Guide DS3 ATM card A 2 DS3 ATM2 card A 5 E1 card A 7 E1 FrameLine card A 9 E3 ATM card A 10 Ethernet 2 card A 13 Ethernet...

Страница 48: ...ect trunk One MAX TNT unit can accommodate a maximum of four DS3 ports two active ports two standby ports Figure A 1 DS3 ATM card Specifications Table A 1 lists the specifications for the DS3 ATM card...

Страница 49: ...ectrical standards DSX 3 per ANSI T1 404 Line buildout 0 225 feet 0 68 6m or 226 450 feet 68 9 137 6m Receive equalization Based on cable length and transmitter Line code Bipolar with 8 zero substitut...

Страница 50: ...hysical Interface Configuration Guide Figure A 2 illustrates a redundant connection Figure A 2 DS3 ATM redundant configuration Table A 2 DS3 ATM card status lights Light Color Description LA Green On...

Страница 51: ...e specifications for a DS3 ATM2 card are the same as those for a DS3 ATM card which are listed in Table A 1 on page A 2 Status lights All status lights except ACT illuminate upon startup or restart an...

Страница 52: ...rimary card fails either because of a failure to boot up or because the card is in a fault state the secondary card takes over For information about configuring a redundant connection see the APX 8000...

Страница 53: ...A 4 E1 card specifications Category Specification Interface standards International Telecommunications Union ITU G 703 G 736 G 775 and G 823 European Telecommunications Standards Institute ETSI 300 1...

Страница 54: ...network line interface when used with coaxial cable adapters is on the transmit side Tx for 1680Kbps network operations The maximum distance between the E1 PRI WAN interface equipment and the MAX TNT...

Страница 55: ...am jacks E1 FrameLine card The E1 frameline card supports 10 unchannelized E1 lines The entire bandwidth of each E1 line can be used for a frame relay connection Figure A 7 shows the E1 FrameLine card...

Страница 56: ...illustrated in Figure A 8 Figure A 8 E3 ATM slot card Specifications Table A 6 provides the specifications for the E3 ATM slot card FAULT RX BYP LOS LOF YEL AIS TX BYP ACT Table A 6 E3 ATM slot card s...

Страница 57: ...to 90 noncondensing Operating temperature 0 to 40 C 32 to 104 F Table A 6 E3 ATM slot card specifications continued Category Specification Table A 7 E3 ATM slot card status lights Light Color Descript...

Страница 58: ...ivate the line Connecting redundant E3 ATM slot cards You can install two E3 ATM slot cards to provide redundancy If the primary card either fails to boot up or is in a fault state the secondary slot...

Страница 59: ...card Figure A 10 Ethernet 2 card Table A 8 lists the specifications for the Ethernet 2 card Table A 8 Ethernet 2 card specifications Category Specification Power requirements 17W Interfaces per card T...

Страница 60: ...s for the Ethernet 3 card Status lights Table A 10 explains the Ethernet 3 card status lights Table A 9 Ethernet 3 card specifications Category Specification Interfaces per card One full duplex Connec...

Страница 61: ...slot card Specifications Table A 11 provides the specifications for the Ethernet 3 ND card Status lights Table A 12 explains the Ethernet 3 ND slot card status lights LEDs Table A 11 Ethernet 3 ND slo...

Страница 62: ...encapsulated data received from or sent to a WAN interface Because the MAX TNT base system provides no HDLC resources you might need to install a Hybrid Access slot card in your unit Keep in mind tha...

Страница 63: ...vices Data and VoIP services Downloaded software licenses determine which MultiDSP services are supported by a particular MAX TNT unit and 48 port MultiDSP card For example if a unit is licensed to ru...

Страница 64: ...specifications for the MultiDSP cards Table A 13 MultiDSP card specifications Category Specification Physical interfaces 48 ports of supported application per 48 port MultiDSP card 96 ports of support...

Страница 65: ...r card One full duplex OC 3c STM 1 SONET SDH Cable requirements Single mode SM cables 9 125 micron optical fiber Connector requirements Must meet JIS C 5973 Optical input avg 32 5dBm minimum 8dBm maxi...

Страница 66: ...gnal AIS or Idle Signal Table A 15 explains the OC3 ATM card status lights Table A 15 OC3 ATM card status lights Light Description YA On indicates the OC3 interface has detected a Far End Receive Fail...

Страница 67: ...Figure A 13 PCTFI card Specifications Table A 16 provides the specifications for the MAX TNT PCTFI slot card Status lights All status lights illuminate upon startup or restart The lights remain illumi...

Страница 68: ...rs with MT RJ connectors at both ends Each fiber must not exceed 2000 feet 610 meters Each peripheral control and timing PCT facility interface link is a duplexed connection with one active and one st...

Страница 69: ...t use the Hybrid Access cards instead Series56 II and Series56 III ports appear in the output of both the HDLC and Modem commands The Series56 II and Series56 III digital modem cards have identical pa...

Страница 70: ...pecifications Category Specification Connectors Fiber SC 1 Interfaces per card One full duplex STM 0 Synchronous Optical Network Synchronous Digital Hierarchy SONET SDH Card dimensions 5 6 inches high...

Страница 71: ...ine HG BAIS Table A 19 STM 0 card specifications continued Category Specification Table A 20 STM 0 card status lights Light Color In on indicates RALM Red All path alarms Can mean any of the following...

Страница 72: ...ed in a MAX TNT shelf for a total of up to 24 ports Figure A 15 shows the SWAN card Figure A 15 SWAN card Specifications Table A 21 lists the specifications for the SWAN card Table A 21 SWAN card spec...

Страница 73: ...the WAN 1 Using the Lucent Serial WAN cable connect the 60 pin D connector to the SWAN card as shown in Figure A 16 Figure A 16 Connecting the SWAN card to the WAN 2 Connect the other end of the cable...

Страница 74: ...ations Table A 22 lists the specifications for the T1 card RX TX SEL FAULT MONITOR Table A 22 T1 card specifications Category Specification Interface standards American National Standards Institute AN...

Страница 75: ...Monitoring the T1 lines with bantam jacks Each T1 card provides transmit and receive bantam jacks to monitor the status of the T1 lines The Tx line carries what the MAX TNT unit transmits to the netw...

Страница 76: ...he T1 FrameLine card LINE 0 1 2 3 4 5 6 7 8 9 FAULT Table A 23 T1 FrameLine card specifications Category Specification Electrical DSX 1 per ANSI T1 102 DSX DS1 per ANSI T1 403 Pub 62411 CSU Line build...

Страница 77: ...the specifications for the T3 card Table A 24 T3 card specifications Category Specification Electrical standards DSX 3 per ANSI T1 404 Line buildout 0 225 feet 0 68 58m or 226 450 feet 68 88 137 6m R...

Страница 78: ...e reset state the Line Rx and Line Tx signals are electrically connected to the Bypass Rx and Bypass Tx jacks respectively When the T3 card passes its POST a relay switch connects the line jacks to th...

Страница 79: ...ions Table A 26 lists the specifications for the unchannelized DS3 card Table A 26 Unchannelized DS3 card specifications Category Specification Electrical DSX 3 per ANSI T1 404 Line buildout 0 to 225...

Страница 80: ...elized DS3 card or other Data Terminal Equipment DTE When the unchannelized DS3 card is not powered or is in the reset state the Line Rx and Line Tx signals are electrically connected to the Bypass Rx...

Страница 81: ...d in Table B 1 Serial port specifications B 1 Ethernet interface specifications B 2 T1 PRI interface specifications B 2 E1 PRI interface specifications B 10 Serial WAN SWAN cable specifications B 15 I...

Страница 82: ...propriate equipment for the type of interface to be installed 10BaseT 100BaseT For a 10BaseT or 100BaseT connection you need a twisted pair Ethernet cable terminated with RJ 45 modular jacks Use an EI...

Страница 83: ...ut internal CSU A T1 PRI port of the MAX TNT that does not have an internal CSU cannot connect directly to the WAN You must connect the port to other equipment that provides the interface to the WAN f...

Страница 84: ...eet standard T1 attenuation and transmission requirements The following specifications are recommended 100 ohm Two twisted pairs Category 3 or better The WAN interface cables and plugs described in th...

Страница 85: ...e verify that the WAN transmits on pins 5 and 4 and receives on pins 2 and 1 Table B 4 and Figure B 2 show the pinouts Figure B 2 RJ 48C RJ 48C straight through cable Table B 4 RJ 48C RJ 48C straight...

Страница 86: ...verify that the WAN transmits on pins 3 and 11 and receives on pins 1 and 9 Table B 5 and Figure B 3 shows the pinouts Figure B 3 RJ 48C DB 15 straight through cable Table B 5 RJ 48C DB 15 straight t...

Страница 87: ...t the WAN transmits on pins 1 and 9 and receives on pins 3 and 11 Table B 6 and Figure B 4 show the pinouts Figure B 4 RJ 48C DB 15 crossover cable Table B 6 RJ 48C DB 15 crossover cable specification...

Страница 88: ...e connects to dual bantam jacks Table B 7 and Figure B 5 show the pinouts Figure B 5 RJ 48C Bantam straight through cable Table B 7 RJ 48C Bantam straight through cable specifications Pair Signal Male...

Страница 89: ...nt Switched 56Kbps and 64Kbps services MultiRate and GloBanD and GVPN in CCITT countries PRI network services Note MAX TNT units can only access Switched 56Kbps services on a T1 access line or a Switc...

Страница 90: ...in this section are available for the unit s WAN interfaces E1 PRI crossover cable RJ 48C RJ 48C Install the RJ 48C RJ 48C crossover cable when the WAN interface transmits on pins 5 and 4 and receives...

Страница 91: ...through cable verify that the WAN interface transmits on pins 2 and 1 and receives on pins 5 and 4 Table B 11 and Figure B 7 show the pinouts Figure B 7 RJ 48C RJ 48C straight through cable Table B 1...

Страница 92: ...straight through cable verify that the WAN interface transmits on pins 3 and 11 and receives on pins 1 and 9 Figure B 8 and Table B 12 show the pinouts Figure B 8 RJ 48C DA 15 straight through cable...

Страница 93: ...he RJ 48C DA cable verify that the WAN interface transmits on pins 1 and 9 and receives on pins 3 and 11 Figure B 9 and Table B 13 show the pinouts Figure B 9 RJ 48C DA crossover cable Table B 13 RJ 4...

Страница 94: ...RJ 48C Bantam straight through cable connects to dual bantam jacks Figure B 10 and Table B 14 show the pinouts Figure B 10 RJ 48C Bantam straight through cable Table B 14 RJ 48C Bantam straight throug...

Страница 95: ...s serial WAN port is compatible with the following two electrical standards V 35 RS 449 422 In the cable wiring tables that follow a MAX TNT unit is the Data Terminal Equipment DTE that connects to a...

Страница 96: ...cifications Serial WAN SWAN cable specifications 3 RD RD 30 29 R T 4 ST ST 41 42 Y AA 5 RT RT 32 31 V X 6 TT TT 38 37 U W 7 DTR DSR 6 11 H E 8 DCD SGND 9 25 F B 9 CTS RTS 7 36 D C Table B 16 V 35 cabl...

Страница 97: ...of a DCE device The RS 449 cable has the pinouts described in Table B 17 Table B 17 RS 449 cable pinouts Pair Signal MAX TNT male DB 44 Host female DB 37 1 FGND RI 1 8 1 15 2 SD SD 39 40 4 22 3 RD RD...

Страница 98: ...Serial WAN SWAN cable specifications Serial WAN cable Figure B 11 and Table B 18 show the pinouts for the V 35 serial WAN SWAN cable Table B 18 Serial WAN cable pinouts J1 Pin J2 Pin 46 A 42 D 43 E 35...

Страница 99: ...Cabling and Connector Specifications Serial WAN SWAN cable specifications MAX TNT Hardware Installation Guide B 19 Figure B 11 Serial WAN cable...

Страница 100: ...7 IDSL cable Table B 19 IDSL cable pinouts Pair P1 Pin P2 Pin P3 Pin J1 Pin J2 Pin Signal 1 36 1 Tip1 1 37 26 Ring 1 2 18 2 Tip 2 2 19 27 Ring 2 3 16 3 Tip 3 3 17 28 Ring 3 4 14 4 Tip 4 4 15 29 Ring 4...

Страница 101: ...5 33 40 Ring 15 16 34 16 Tip 16 16 35 41 Ring 16 17 36 17 Tip 17 17 37 42 Ring 17 18 18 18 Tip 18 18 19 43 Ring 18 19 16 19 Tip19 19 17 44 Ring 19 20 14 20 Tip 20 20 15 45 Ring 20 21 12 21 Tip 21 21 1...

Страница 102: ...2 29 Ring 4 5 23 5 Tip 5 5 24 30 Ring 5 6 25 6 Tip 6 6 26 31 Ring 6 7 32 7 Tip 7 7 33 32 Ring 7 8 34 8 Tip 8 8 35 33 Ring 8 9 36 9 Tip 9 9 37 34 Ring 9 10 18 10 Tip 10 10 19 35 Ring 10 11 16 11 Tip 11...

Страница 103: ...16 16 7 41 Ring 16 17 4 17 Tip 17 17 5 42 Ring 17 18 2 18 Tip 18 18 3 43 Ring 18 19 1 19 Tip19 19 20 44 Ring 19 20 21 20 Tip 20 20 22 45 Ring 20 21 23 21 Tip 21 21 24 46 Ring 21 22 25 22 Tip 22 22 26...

Страница 104: ...ware Installation Guide Cabling and Connector Specifications IDSL cable specifications Figure B 12 HDSL dual 50 pin telco to triple DB 37 cable All three ends above have same pinouts Both ends above h...

Страница 105: ...L cable Table B 20 ADSL cable pinouts Pair P1 Pin P2 Pin P3 Pin P4 Pin J1 Pin Signal 1 36 1 Tip1 1 37 26 Ring 1 2 18 2 Tip 2 2 19 27 Ring 2 3 16 3 Tip 3 3 17 28 Ring 3 4 14 4 Tip 4 4 15 29 Ring 4 5 12...

Страница 106: ...5 15 17 40 Ring 15 16 14 16 Tip 16 16 15 41 Ring 16 17 12 17 Tip 17 17 13 42 Ring 17 18 10 18 Tip 18 18 11 43 Ring 18 19 39 19 Tip19 19 37 44 Ring 19 20 18 20 Tip 20 20 19 45 Ring 20 21 16 21 Tip 21 2...

Страница 107: ...co to quadruple DB 37 cable SDSL cable specifications Figure B 14 and Table B 21 show the pinouts for the 50 pin telco to dual DB 37 SDSL cable Table B 21 SDSL cable pinouts Pair P1 Pin P2 Pin J1 Pin...

Страница 108: ...7 33 Ring 8 9 4 9 Tip 9 9 5 34 Ring 9 10 2 10 Tip 10 10 3 35 Ring 10 11 1 11 Tip 11 11 20 36 Ring 11 12 21 12 Tip 12 12 22 37 Ring 12 13 36 13 Tip 13 13 37 38 Ring 13 14 18 14 Tip 14 14 19 39 Ring 14...

Страница 109: ...8 19 8 19 Tip19 19 9 44 Ring 19 20 6 20 Tip 20 20 7 45 Ring 20 21 4 21 Tip 21 21 5 46 Ring 21 22 2 22 Tip 22 22 3 47 Ring 22 23 1 23 Tip 23 23 20 48 Ring 23 24 21 24 Tip 24 24 22 49 Tip 24 Table B 22...

Страница 110: ...current a 48V battery is connected between pins 25 and 50 10 10R 35 10T 11 11R 36 11T 12 12R 37 12T 13 13R 38 13T 14 14R 39 14T 15 15R 40 15T 16 16R 41 16T 17 17R 42 17T 18 18R 43 18T 19 19R 44 19T 2...

Страница 111: ...Cabling and Connector Specifications SDSL cable specifications MAX TNT Hardware Installation Guide B 31 Figure B 14 SDSL 50 pin telco to dual DB 37 cable...

Страница 112: ......

Страница 113: ...hium battery The normal operating life of this battery exceeds five years Make sure that only trained engineers authorized by Lucent open the MAX TNT shelf controller for testing maintenance installat...

Страница 114: ...cifications for MAX TNT units Governmental notices Information about governmental notices required for the United States U S FCC Part 68 Notice FCC Part 68 Notice Canada the European Union Australia a...

Страница 115: ...of the wire you use to connect to the unit s alarm relay must be based on the current flow of the circuit that the relay is attached to and the capacity of the alarm relay Because the unit s alarm rel...

Страница 116: ...midity In general cooler environments are better Humidity must be high enough to prevent accumulation of static electricity but low enough to prevent condensation An operating temperature of 32 to 104...

Страница 117: ...ng configuration interface through serial cable 3 11 connections redundant T3 A 33 connectors E1 PRI specifications B 10 T1 PRI specifications B 9 cooling requirements for 3 1 CSU line compatibility B...

Страница 118: ...the LAN 3 12 installing the MAX TNT chassis 3 1 maximum distance between MAX TNT and WAN interface equipment A 9 overview 3 1 power supplies 3 8 preparing for 2 3 required tools 2 3 requirements for 2...

Страница 119: ...2 ADSL cabling B 25 alarm relay C 3 AUI B 2 battery C 1 dimensions 3 4 E1 PRI WAN ports B 15 environmental C 4 Ethernet interface B 2 general C 1 IDSL cabling B 20 physical C 4 power C 2 serial port...

Страница 120: ...ons A 34 USOC jacks and codes C 3 V V 35 cabling for DB 44 B 15 W WAN connecting E1 line to A 9 connecting E3 line to A 13 connecting T1 line to A 30 connecting T3 card to A 33 WAN Wide Area Network p...

Отзывы: