Lucent Technologies Lineage
®
2000 25A Ferroresonant Rectifier J85502A-1
Issue 4 May 1998
Spare Parts and Replacement Procedures 8 - 5
Replacing CM1
Option Board
1. Turn the rectifier POWER switch Off.
2. Turn the rectifier (CBA1) DC OUTPUT circuit breaker
Off (down).
3. At the ac service panel supplying power to the rectifier,
remove the input fuses assigned to the rectifier, or turn the
circuit breaker Off.
4. At the plant controller, remove the REG fuse associated
with the rectifier.
5. At the rectifier, loosen the locking screws and open the
rectifier door.
6. Locate the CM1 option board.
7. Using a drawing of the option board like that in Figure 6-2,
record where each cable connects to the board.
8. Remove all cables from CM1 by unlatching first, then
pulling the cable connector.
9. Remove the four quick-disconnect connectors from the
CM1 option board.
10. Remove header connectors from CM1.
11. Remove the two mounting nuts and associated
lockwashers securing CM1.
12. Verify that the new option board has the correct straps and
resistors in place. If not, modify the board according to
“Modifying the CM1 Option Board.”
13. Position the new CM1 board over the four support
standoffs. Verify that each latch snaps and locks in place.
Caution
Support the CM1 option board with your hands when
connecting and disconnecting the cables, or damage to the
board may result.
Do NOT disconnect cables by pulling the cable.