Local Alarms, Indicators And Readout
The LubriMist® Model JD is equipped with sensors which monitor different operating functions for the Main
Oil Mist Generator. The operating status of each of these operating functions is enunciated by a display
message on the liquid crystal display.
The signals from the sensors are fed into the conditioning circuits of the controller. The conditioning
circuit signal is interpreted and scaled by the program to produce gauge values. See "Reading Unit
Operating Conditions" for instructions on how to check the operating conditions.
The program performs an ordered series of control set point checks for the maximum and minimum
values of each monitored function. If the current value exceeds a maximum setting (high alarm) or is less
than a minimum setting (low alarm), the
JD
controller recognizes the fault condition and locally identifies the
alarm.
The Model "JD" locally identifies and indicates a fault condition in two ways. They are: 1) fault
message displayed on the liquid crystal display and, 2) red and green externally mounted unit status lights.
Содержание JD
Страница 2: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 2 of 152 ...
Страница 35: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 35 of 152 COMMISSIONING ...
Страница 43: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 43 of 152 OPERATING GUIDE ...
Страница 110: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 110 of 152 TROUBLE SHOOTING GUIDE ...