Tag Detail for NEC Model JD
All LubriMist® Model JD Oil Mist Generators are labeled as follows:
M ax Inlet Air P ressure 150 PS IG / 10.3 B ar
C lass I, Zone 2, G roup IIB + H 2, T
D ivision 2 G roups B, C , D - T
Lubrication S ystem s C o. H ouston Texas U SA
S eries N o.
A m ps
Listed O il M ist G enerator for H azardous Locations
C < T am b < +60
I
C lass
O perating Tem perature -20
713/464-6266
e-m ail Info@ LSC .C O M
l
l
°
Volts A C
S erial N o.
M odel N o
LubriM ist
50 / 60 H z
®
L
U
Fax 713/464-9871
U S
23 PN
LIS TED
C
®
C
°
Data Ref.
Description
Example
Model No.
Per Customer Purchase Order and CFH RS Job Order.
See ”
LubriMist®
Model JD Model Code Designation Key
” ____________________________
JD-NAEXXX
Serial No.
Unique Serial Numbers are to be issued to each machinery item. The CFH RS Sales Order
Number is used as the serial number prefix, and is followed with a designation for mist flow
capacity specific to the machine being manufactured. The last designation differentiates between
multiple machineries sold under the same sales order.
Sales
Order
Number
Mist
Generating
Capacity
060 = 60 Bearing Inch
213 = 213 Bearing Inch
475 = 475 Bearing Inch
933 = 933 Bearing Inch
Item
X
of
Y
quantity
produced
on
S.O.
______ - ___ - ___
Volts
Machinery is available for connection to either 115 VAC or 230 VAC single-phase electrical
power supply. The purchaser specifies the electrical power requirement. Reference ”LubriMist®
Model JD Model Code Designations
”
For
115
VAC
power____________________________
For
230
VAC
power____________________________
115
230
Power
The maximum operating power requirement for the “Main” oil mist generator at the specified
voltage.
Machinery for use at 115 VAC___________________
Machinery for use at 230 VAC___________________
The maximum operating power requirement at the specified voltage with the power switches for
both the “MAIN” and the “Auxiliary” oil mist generators in the ON position.
Machinery for use at 115 VAC___________________
Machinery for use at 230 VAC___________________
8 Amps
4 Amps
12 Amps
6 Amps
Содержание JD
Страница 2: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 2 of 152 ...
Страница 35: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 35 of 152 COMMISSIONING ...
Страница 43: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 43 of 152 OPERATING GUIDE ...
Страница 110: ...LubriMist Model JD Oil Mist Generating System Installation and Operating Manual Page 110 of 152 TROUBLE SHOOTING GUIDE ...