Installation, operating and maintenance instructions
Active chilled beams HDF-600, ceiling installation
1.
Safety
Assembly, dismantling and mainte
nance must be performed by trained
personnel in order to achieve reliability,
safety and best results.
1.1
Explanation of symbols and hints
Operating safety symbol
This symbol is placed alongside every
operating safety instruction in these ope
rating instructions, wherever there is a
danger to life and limb. Observe these in
structions and in such cases proceed with
extreme caution.
Pass on all the operating safety instructions to other
users. In addition to the instructions contained in these
operating instructions, the generally applicable safety
and accident prevention regulations must be observed;
as shown here, for example: Warning of hazard point.
Information symbol
This
information
symbol
is
placed
alongside those points in the manual
which must be specifically observed in
order to ensure that the guidelines, regu
lations, instructions and correct opera
ting sequences are observed and to pre
vent damage to or destruction of the unit
and/or other components in the system.
These mandatory symbols are linked to
the operating safety instructions and
show which protective measures must be
complied with at the appropriate worksta
tions and therefore specifically mandate a
certain action, as shown here as an exam
ple: Wear protective gloves.
These prohibition symbols are linked to
the operating safety instructions banning
a dangerous or risky action, as shown
here as an example: Do not touch.
1.2
Operating safety instructions
Carefully read the safety instructions before using any
LTG active chilled beam. Always follow the safety instruc
tions!
The units meet any pertinent safety standards.
The installation and maintenance of ac
tive chilled beams may be dangerous be
cause of high pressures and electrical
components being alive. Therefore, the
installation, maintenance, and repair
must be performed by qualified and
trained staff only.
Safety instructions in the technical documentation and
on unit labels must be followed at all times.
Do not open the unit for cleaning, maintenance, or repair
and do not remove covers and casings (air diffuser) un
less all conducting lines have been completely
disconnected.
In the heating mode a tem
perature of up to +176 °F
may be achieved. Water-
carrying parts may be hot
so do not touch with your
bare hands to avoid burns.
Heat exchanger blades and
housing parts are sharp-
edged.
The standard version of the
heat exchangers is de
signed for an operating
pressure of 145 psi (test
pressure 232 psi). High wa
ter pressures may be haz
ardous. Higher operating
pressures, therefore, re
quire LTG's express per
mission.
Parts and tools.
When working overhead.