7. Function List
7-8
7.3 Function Group 2
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
H 0
[Jump code] 1/95
This parameter sets
the code number to jump.
1
O
H 1
[Fault
history 1]
-
This parameter stores
information on the types
of faults, the frequency,
the current and the
Accel/Decel condition at
the time of fault.
The last fault is
automatically stored in
the H 1- [Fault history 1].
nOn
-
H 2
[Fault
history 2]
-
nOn
-
H 3
[Fault
history 3]
-
nOn
-
H 4
[Fault
history 4]
-
nOn
-
H 5
[Fault
history 5]
-
nOn
-
H 6
[Reset fault
history]
0/1
This parameter clears
the fault history saved in
H 1-5.
0
O
H 7
[Dwell
frequency]
F23/400
[Hz]
When run frequency is
issued, motor starts to
accelerate after dwell
frequency is applied to
the motor during H8-
[Dwell time].
[Dwell frequency] can
be set within the range of
F21- [Max frequency] and
F23- [Start frequency].
5.0
X
H 8
[Dwell time] 0/10
[sec]
This parameter sets the
time for dwell operation.
0.0
X
H10
[Skip
frequency
select]
0/1
This parameter sets the
frequency range to skip to
prevent undesirable
resonance and vibration
on the structure of the
machine.
0
X
H11
1)
[Skip
frequency
low limit 1]
0/400
[Hz]
Run frequency cannot
be set within the range of
H11 thru H16.
The frequency values
of the low numbered
parameters cannot be set
above those of the high
numbered ones.
10.0
X
H12
[Skip
frequency
high limit 1]
15.0
X
H13
[Skip
frequency
low limit 2]
20.0
X
Содержание SV004iC5-1F
Страница 8: ......
Страница 22: ...3 Wiring 3 6 ...
Страница 38: ...5 Programming Keypad 5 14 ...
Страница 42: ...6 Basic Operation 6 4 ...
Страница 64: ...7 Function List 7 22 ...
Страница 74: ...9 Specifications 9 4 ...