Duct flow

 

o

 

Air speed from differential pressure (Pitot or Darcy) 

o

 

Volumetric air and mass flow 

o

 

Number of air changes 

 

 

Radiometry

 

o

 

Insolation time 

o

 

UV index (DLE) 

o

 

UV exposure level 

o

 

Light intensity 

o

 

UVA density 

o

 

Day light factor 

 

 

Actuators operations(*)

 

o

 

Actuation status calculated with AND operator 

o

 

Actuation status calculated with OR operator 

o

 

Actuation logics status calculated with AND operator 

o

 

Actuation logics status calculated with OR operator 

 

 

Others

 

o

 

Evaporation calculation based on the evaporimeter level 

o

 

Soil volumic humidity with permittivity 

o

 

Atmospheric pressure at sea level 

o

 

Total count 

o

 

Delta with previous value 

o

 

Reprocess measure 

o

 

Correct level 

 
 
(*)  Calculated  measures  available  only  for  E-Log  datalogger  with  firmware  from  2.13.1  version; 
calculated measures associated with 3DOM software from 3.8 version. 
These measure are set a fixed update time of 1 second: the update of value of calculated measure on 
the actuator is always 1 second delay compared to the status recorded by internal actuation logic. 
Now is therefore possible to process and record the actuator status or display it as an instantaneous 
value without having to carry the electrical signal of the actuator in an input of the datalogger. Now 
it is also possible make complex algorithms through a combination  of actuation logics status  with 
other calculated measures (typically addition and multiplication), overcoming the limits of the use 
of a single operator (AND and OR) and giving the inputs for the acquisition of real sensors.  
 
 
With 

3DOM 

you can choose which quantities to have the instrument calculate and select the direct 

measures which allow their calculation. 
 
Some  calculations,  frequently  used  in  agro-meteorology,  such  as  wind  direction  or  integral 
radiation, are easily obtained from the integral mathematical calculation. 
 
 
 
 
 

Содержание E-Log

Страница 1: ...Cod INSTUM_00351_en E Log User s manual Updated on 09 18 2017...

Страница 2: ...this manual may be changed without prior notification No part of this manual may be reproduced neither electronically or mechanically under any circumstance without the prior written permission of LSI...

Страница 3: ...g additional features 26 5 1 Starting and running the survey 26 5 1 1 Checking the power supply voltage 26 5 2 Acquisition and calculation of measures 26 5 2 1 Acquisition from sensors with serial or...

Страница 4: ...ransmission using TCP IP 47 5 6 10 E Log connected like master slave mode 47 5 6 11 E Log with ZigBee radio 48 5 7 Operating at low energetic consumption 51 6 Appendixes 53 6 1 Technical specification...

Страница 5: ...iner Power the instrument in a suitable manner Connect the instrument to the power supply indicated in the model in your possession Carry out all connections in a suitable manner Pay strict attention...

Страница 6: ...nvironmental protection and collection LSI LASTEM advises to handle E Log as waste of electrical and electronic equipment WEEE It is therefore not to be collected with any other kind of waste LSI LAST...

Страница 7: ...and the terminal connections to power the instrument power supply or battery The terminal board is protected by a carter Picture 1 that covers the terminals remove it by pressing slightly on both sid...

Страница 8: ...he right hand side panel in this case the positive pole is the one inside the connector In any case pay attention not to invert the power polarity although the instrument is protected from wrong proce...

Страница 9: ...e to consider both the energetic saving and the time the sensor needs to initialize The association between input and switching power is fixed as shown in the table below The number of the terminal is...

Страница 10: ...o return a voltage signal from the current generated by the sensor Program 3DOM supplies a library for the setting of the LSI LASTEM sensors including some powered outputs for such models the settings...

Страница 11: ...ized output Picture 6 Moreover if you want connect to E Log some LSI LASTEM portable probes type BST BSU BSO or sensors not branded LSI LASTEM which mount minidin connectors you have to use ELA115 int...

Страница 12: ...All sensors generating tension or current signals with or without external power can be connected to single ended inputs see connection scheme Sensors with analogue signal single ended mode The drop...

Страница 13: ...ng to E Log model Both serial ports leave our factory with the following default configuration Baud rate 9600 bps Data bit 8 Stop bit 1 Parity none Network address 1 Flow control RTS signal only The i...

Страница 14: ...med with 3DOM 3 2 Configuring the operative modes LSI LASTEM supplies the instrument with a standard configuration In order to modify the configuration parameters to one s specific needs connect a PC...

Страница 15: ...LSI LASTEM E Log User s manual 15...

Страница 16: ...ouses the keyboard bright indicators led and the display used to check if the instrument is working properly The lower part includes a carter to protect the electrical connections to the terminals loc...

Страница 17: ...easure list Holds releases measure scrolling Switches the display off and on see 4 3 4 While showing diagnostic information Shifts to the display window of the values of the measures If applicable it...

Страница 18: ...uuuuuuuu serial number or instrument number settled by the user These informations are also available while the instrument is working and can be called by simply using the keyboard to select this win...

Страница 19: ...ow of the system in order to decode this error go to 6 3 mmmm data memory capacity in kByte wwww hexadecimal number that expresses the value of the position writing in the elaborated data memory the s...

Страница 20: ...network address of the instrument yyyyy communication rate bit rate of the serial port The character shows the current serial port for this port are valid the modification commands of the bit rate fr...

Страница 21: ...ice if the forcing is also imposed to an actuator state that can assume 0 or 1 value means that actuator will never be change by any internal logic except the commands received from remote through CIS...

Страница 22: ...ers its use only for serial port 1 alternatively the display goes to the next diagnostic window In case the configuration considers the use of the GPRS modem but the modem is switched off the window s...

Страница 23: ...o No Conn status of not established connection to the PAN o Fail radio module absent or not working x indicates the modem status it can take these values o 0 the modem has undergone a hardware reset...

Страница 24: ...orrect transmission o 2 failed transmission o 22 address node not valid o 33 failed confirmation of network acknowledge o 34 no network connection o 35 addressing of network node obtained indipendentl...

Страница 25: ...cation indicator Description Off Instrument switched off or low feeding voltage min 7 V Single quick green blinking Instrument switched on Regular operation acquisition mode Three quick green blinking...

Страница 26: ...it must be 7 V at least In case it isn t enough E Log closes the survey in progress and stands by During the stand by it checks every minute the power supply voltage until it ll reach the minimum val...

Страница 27: ...Gill protocol Gill format polar continuous E Log supports the connection to one sensor 3DOM software programs the used protocol it isn t possible use more than one protocol and for this reason it isn...

Страница 28: ...nsor equivalent to character ASCII Q is considered by E Log like value 1 the next letter R like value 2 and so on 3DOM application automates some configuration operations by means of its sensors libra...

Страница 29: ...d direction and relative humidity are excluded Linearized quantity control the instrument produces null output when receiving null input All above parameters are indicated in section Measure propertie...

Страница 30: ...ndicating among others its serial number When operating in this acquisition mode the instrument s LED will blink differently see 4 4 Please note that in this condition the instrument Acquires all sens...

Страница 31: ...of all primary measures that allow the estimate of calculated measures a calculated measure can be a primary measure for new calculated measure 2 Collection of the value of primary measures if at lea...

Страница 32: ...percentage It is not possible to combine arithmetical and vectorial calculations for each specific measure Programm 3DOM can be used to program the elaboration parameters The instrument doens t have i...

Страница 33: ...gra Resulting average direction Dmr Vel Dir rad Cos Vel Dir rad Sin gra atan2 Resulting average speed Vmr n Vel Dir rad Cos Vel Dir rad Sin 2 2 Direction s standard deviation sigma theta DevStandDir 2...

Страница 34: ...ht be lost for this reason we advise transferring the elaborations which have not yet been transmitted to the PC before switching off E Log 5 4 1 Memory autonomy Depending on the chosen configuration...

Страница 35: ...uator even if this occurs temporally after the deactivation The programming of the actuation logics happen by means of the 3DOM program according to two different phases 1 Selection of the logics and...

Страница 36: ...he surface of the water doesn t allow the right evaporation in the morning and in the evening 5 5 3 Start precipitation alarm The logic uses a measure connected to a rain gauge to detect the start pre...

Страница 37: ...s both univocally and simultaneously To the threshold values can be applied a further hysteresis value this can avoid continuous alarm state changes in case the measure value moves nearly around the t...

Страница 38: ...and at the same time lesser than the maximum threshold value return to no alarm condition when the measure value is lesser than the minimum threshold value or greater than the maximum threshold hyster...

Страница 39: ...ust be consecutively ordered the list cannot include any measures that shouldn t be considered in the comparing because the logic programming needs the ordinal numbers of the first and last measure Th...

Страница 40: ...off times If timer type is not cyclic the day time of power on the actuator and the day time of power off This logic is joinable with other logics in AND mode for example to allow the alarms activatio...

Страница 41: ...ith GSM or GPRS modem in this case follow the instruction in 5 7 to reduce the modem power consumption To execute local communications with E Log remove the connection between the modem and serial por...

Страница 42: ...ine sensor Boschung sensor data acquisition from Boschung sensor Some LSI LASTEM applications like i e InfoPanel are able to obtain the instantaneous measures data from serial port 2 In this way the s...

Страница 43: ...ral Acquisition of sampled instantaneous values and transmission from connected instrument X Komoline Acquisition of sampled instantaneous values and transmission from connected instrument X Boschung...

Страница 44: ...ses the GPRS data packet transmission and TCP or FTP protocols DEA717 DEA718 with E Log FW until V 2 29 00 DEA718 1 with E Log FW V 2 30 00 or later to allow the continuous transmission with transmiss...

Страница 45: ...eceived data of some parameters you must follow the following tables OVM Obstruction to Vision Message Value Meaning 0 No obstruction 1 HZ Haze 2 FG Fog SFM Self test and Monitoring Subparameter Forma...

Страница 46: ...two different transmission s modes Through TCP socket Through FTP protocol The TCP socket connection allows to have greater control over the datalogger against the FTP protocol because not only the el...

Страница 47: ...nding and closing file Check the log recorded by the FTP server 28 30 33 GPRS context creation and network access Using 3DOM verify the APN connection parameters against the SIM used inside the modem...

Страница 48: ...ters of port 2 Network Address 1 and Spontaneous transmission Rate 0 input one rate lower than the acquisition rate of fast serial measure set up on master we recommend the input of slave s transmissi...

Страница 49: ...plications buildings and plants for outdoor applications that the signal encounters during their journey to the destination of communication Specifications Performances Indoor standard range up to 60...

Страница 50: ...install the network devices Put the devices in place making attention to distance as the crow files among respective nodes remain within max range specified in specifications and considering the obsta...

Страница 51: ...structure through Master any time you need it Note 1 in a network in case of reprogramming of Master without modify of configuration of Slave instruments which are turned on and active in acquisition...

Страница 52: ...so they aren t operating Disable communication protocol on serial port 2 in case it isn t used or in case it corresponds to following types TTY Modbus Gill anemometer ATTENTION Default configuration...

Страница 53: ...er Temperature drift scale 300 1200 mV 0 01 FSR 10 30 C scale 39 mV 0 01 FSR 10 30 C scale 78 mV 0 01 FSR 10 30 C Digital inputs Number of digital inputs 4 like follow 2 inputs for sensors with optoel...

Страница 54: ...Power Input voltage DC 10 14 V Average power consumption without probes feed 12 V 8 channels acquisition display power on 136 mW 8 channels acquisition display power off 115 mW Power down 4 mW Protec...

Страница 55: ...ximum o Totalization o Angular average Thermo hygrometric quantities UNI EN ISO 7726 ISO WD 7730 VDI 3786 o Relative humidity with psychrometric calculation dry humid bulb o Absolute humidity o Specif...

Страница 56: ...ociated with 3DOM software from 3 8 version These measure are set a fixed update time of 1 second the update of value of calculated measure on the actuator is always 1 second delay compared to the sta...

Страница 57: ...ument using 3DOM see 3 1 4 if the error occurs again contact LSI LASTEM technical support for assistance including the current configuration file 5 Search data in memory If the error occurs immediatel...

Страница 58: ...ers that the error has already been found by the person using the computer In both cases the reset operation will locally switch off the optical indicator Err eliminate the error number from the diagn...

Страница 59: ...ation with PC With or without terminals for connection of sensor cables fixed or removable With or without alphanumerical display and keyboard Code Power supply 12 Vdc Built in Zigbee radio Fixed term...

Страница 60: ...LSI LASTEM E Log User s manual 60 6 6 Mask of terminal board...

Страница 61: ...LSI LASTEM E Log User s manual 61 6 7 Connection cables...

Страница 62: ...LSI LASTEM E Log User s manual 62 6 8 Declaration of Conformity...

Отзывы: