LSI LASTEM E-Log – User’s manual
23
mm:
number of measure in alarm conditions, according to the status obtained by the realization
algorithm associated with the same measure. The window can display max 26 alarm
measures (the first in the list order).
If no actuation algorithm has been programmed, the window cannot be displayed.
Key
to shift to diagnostic window type 7 (available only for ELO505 and ELO515 models):
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Z
i
g
B
e
e
S
N
:
n
n
n
n
n
n
n
n
S
t
a
t
:
a
a
a
a
a
a
(
y
x
)
P
A
N
:
p
p
p
p
p
O
C
:
o
o
S
S
:
s
s
%
R
C
:
1
0
where:
ZigBee indicates the radio type mounted on the instrument (if “ZigBee#”, the radio is a low
power version);
nnnnnnnn
indicates the serial number of ZigBee radio, corresponding to the lower part (less
significant) of the full address of ZigBee network;
aaaaaaaaa
indicates the radio connection status and it can take these values:
o
Undef.
: undefinite status;
o
Init…
: radio module in progress of initialization;
o
Init OK
: radio module initialized successfully;
o
Conn OK
: status of correct connection to the PAN;
o
No Conn
: status of not established connection to the PAN;
o
Fail
: radio module absent or not working.
x
indicates the modem status; it can take these values:
o
0
: the modem has undergone a hardware reset;
o
1
: the modem has undergone a reset caused by a watchdog (blocked program);
o
2
: connection to the PAN occurred;
o
3
: status not related to the PAN;
o
6
: master modality actived.
y indicates the radio power on status in a Slave datalogger and it can take these values:
o
W
: wake status, radio is active;
o
S:
sleep status, radio in low power standby mode.
It is possible switch on the radio on Slave instrument pressing
key from this window.
ppppp
indicates the programmed identity number of the PAN (a value from 1 to 65000);
oo
indicates the channel number used by the radio network (tipically from 1 to 14; up to 16
if using low power radio); it appears only when PAN is connected;
ss
indicates the signal strenght and it is expressed as a percentage; it is the received power of
the radio signal of the last instrument directly connected (not include the intermediate
repeaters);
rr
indicates the numbers of slave type nodes remaining available for connection to the
instrument (maximum 10 for master and maximum 12 for repeater); it is effective only for
master and repeater.
Содержание E-Log
Страница 1: ...Cod INSTUM_00351_en E Log User s manual Updated on 09 18 2017...
Страница 15: ...LSI LASTEM E Log User s manual 15...
Страница 60: ...LSI LASTEM E Log User s manual 60 6 6 Mask of terminal board...
Страница 61: ...LSI LASTEM E Log User s manual 61 6 7 Connection cables...
Страница 62: ...LSI LASTEM E Log User s manual 62 6 8 Declaration of Conformity...