NO DISPLAY AT REAR OF HANGER ASSEMBLY
Ensure power to fixture is live and on a non-dimmed line.
Ensure E-Stop is not engaged
Inspect supply wire for damage
and that plug is inserted and twisted to lock into
position at head
Inspect U ground plug contacts.
FIXTURE DOESN’T RESPOND TO ANY FUNCTIONS
REQUESTED FROM HAND CONTROLLER
Establish power is correct and display is functioning properly, see above.
Test with another hand controller if available. If still unresponsive proceed to
next step.
Remove DMX connectors and inspect contact pins for damage and no signs of
corrosion. Note all five wires and pins are required to operate hand controller.
Plug hand controller directly into fixture, at this point the hand controller
should light up and DMX light on the fixture should also light up. At this point
if the unit is not operational test with another hand controller.
If still not operational, place fixture into DMX mode and test with an
alternative DMX source.
Call for service.
TILT OR PAN NOT OPERATING CORRECTLY.
Head moves freely without control:
This may indicate the fixture has received impact and the drive has been
damaged.
Remove from service.
Head not moving on one axis, but the other axis is fine
Test with another hand controller if available. If still unresponsive proceed to
next step.
If any of these conditions exist, suspend use of the product and call for service.
There are no user serviceable parts.
Press function key and listen for drive motor, if drive motor is heard this
would
indicate the
drive system has
become disengaged.
If no motor noise is heard , this could indicate a faulty motor or control board
Check hanger display for proper addressing and mode.
It is important to note that the LRX fixture will not begin responding to a
newly selected FIXTURE/DMX address until it has been stored.
Ensure the address at the fixture matches the address on the hand controller.