VULTURE SPECIFCATIONS
Electrical:
Volts: 90-240 AC – non-dimmed feed line.
Hertz: 50/60
Amps: 2.0 - 7.0 with Trolley
U- Ground plug
Battery 12VDC
Data: XLR 5 pin connector
Physical:
Tilt: 40 degrees above horizontal to 90 degrees below horizontal
Pan: 340 degrees
Weight: 120 pounds approx.
Fixture mounting hooks have been designed to mate with truss diameter
chords not greater than two inches (50.8mm).
INSTALLATION OF FIXTURES
TELESCOPIC TYPE MAN LIFTS
THIS FIXTURE MUST BE MOUNTED ON A LEVEL TRUSS.
Installation structure must be designed and approved to safely carry all
anticipated loads.
It is the user’s responsibility and obligation to determine and comply with all
applicable laws and regulations.
The installation and operation of this unit must be carried out by authorized
and qualified personnel.
Hanger bolts in hanger assembly must be installed. Both ratchet straps must
be clipped onto their respective anchor point.
Ratchet straps require minimum of 1.5 wraps on the ratchet to ensure they
remain tight.
Always use approved safety cables secured to a point capable of supporting
the total weight of the load.
All power and data cables
must have a strain relief attached.
If cable rollers are required refer to “LRX Cable Roller” manual.